BODTrakⅡ Biochemical Oxygen Demand Analyzer, 0-35,0-70,0-350,0-700 mg/L, Hach (CAT#: STEM-AI-0676-YJL)

Highlights

Simulate the process of microbial degradation of organic matter in nature, which is closer to the real situation
Continuous reading and graphic real-time display of changes in the measurement process
6 independent measurement channels

Cat Number: STEM-AI-0676-YJL

Application: It is mainly used to monitor the pollution status of organic matter in surface water bodies, measure the organic matter pollution load of sewage and wastewater, and evaluate the biodegradability of sewage and wastewater.

Model: BODTrakⅡ

Add to Cart



Description

BODTrakⅡ Biochemical Oxygen Demand Analyzer, 0-35,0-70,0-350,0-700 mg/L, model BODTrakⅡ is manufactured by Hach. Biochemical oxygen demand (BOD) refers to the amount of oxygen consumed when organic matter in water is biochemically degraded by microorganisms, and is a comprehensive indicator reflecting the content of organic pollutants in water. BODTrak® II Biochemical Oxygen Demand Analyzer uses the differential pressure measurement principle to simulate the biodegradation process of organic matter in nature. The oxygen in the air above the test bottle continuously replenishes the dissolved oxygen consumed in the water, and the CO2 produced during the degradation of organic matter is absorbed by the potassium hydroxide in the sealing cap. The pressure sensor monitors the variation of the oxygen pressure in the sampling test bottle at any time. Establishes a correlation between the Biochemical Oxygen Demand (BOD), which corresponds to the amount of oxygen consumed in the test bottle, and the gas pressure, allowing accurate BOD measurement. The test results are displayed graphically on the screen, and the BOD value will be directly displayed on the instrument screen in mg/L.

Specification

Measuring range: (mg/LO2) 0-35, 0-70, 0-350, 0-700
Sensor type: integrated microcomputer sensor
Data display: 360 data points/sample can be saved, and the measurement curve of each sample can be displayed graphically
Number of samples: 6/time (492mL/bottle)
Operating temperature: 20℃ (68°F)
Instrument power supply: 110-240V, 50/60Hz
Size: 28.9x26x9.8cm

Features

Simulate the process of microbial degradation of organic matter in nature, which is closer to the real situation
Continuous reading and graphic real-time display of changes in the measurement process
6 independent measurement channels
Automatic shutdown, automatic data collection
Direct readout of measurement results in graphics
pointer indication in the graph
Graphical display of BOD value and culture time
Compared with the dilution inoculation method, it is simple and convenient