Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Carbon Dioxide Cell Incubator, Water Jacket, Dimensions 41×40.5×51cm (CAT#: STEM-GLE-0942-LGH)

Highlights

It adopts water jacket or air jacket structure, and the studio adopts high-quality stainless steel plate
It is made and equipped with an air duct, and a fan is installed to form forced convection, which improves the box
Uniformity of internal temperature and CO2 concentration

Cat Number: STEM-GLE-0942-LGH

Application: Carbon dioxide cell incubators are specially designed for animal cells and tissue culture, and are widely used in medical units, life sciences, immunology, genetics, medicine and other fields.<br />It can be used for the cultivation of common microorganisms.

Model: HWJ-2-80

Add to Cart



Description

It adopts water jacket or air jacket structure, and the studio adopts high-quality stainless steel plate
It is made and equipped with an air duct, and a fan is installed to form forced convection, which improves the box
Uniformity of internal temperature and CO2 concentration
When the box door is opened, the fan is automatically turned off (WJ-3 type shuts off the CO2 at the same time)
intake valve) and stop heating to reduce pollution caused by the entry of air
dye. The temperature is controlled by microcomputer data analysis and intelligent P.I.D.
High speed and strong anti-interference ability. And three probes are used to control the box temperature,
The water temperature and door temperature make the temperature of the studio with high precision and little fluctuation. (air jacket type
It is a double probe, which controls the temperature of the box and the door separately)
Light touch adjustment switch, light and flexible. The displayed and set parameters are
With digital display, each working status has LED indication
It has various protection functions such as over-temperature, water shortage, and gas cut-off to ensure the safety of the equipment.
fully operational
UV sterilization lamps are used to reduce contamination
Natural evaporation and humidification to maintain a better humidity in the studio

Specification

Temperature control range: room temperature +3℃ ~60℃;
Temperature fluctuation: ±0.2℃
Temperature uniformity: ±0.3℃
CO2 concentration control range: 0~20%;
Mirror stainless steel inner tank, four corners and half circular arc design
Tempered glass interior door
Tank size: 41×40.5×51

Features

It adopts water jacket or air jacket structure, and the studio adopts high-quality stainless steel plate
It is made and equipped with an air duct, and a fan is installed to form forced convection, which improves the box
Uniformity of internal temperature and CO2 concentration
When the box door is opened, the fan is automatically turned off (WJ-3 type shuts off the CO2 at the same time)
intake valve) and stop heating to reduce pollution caused by the entry of air
dye. The temperature is controlled by microcomputer data analysis and intelligent P.I.D.
High speed and strong anti-interference ability. And three probes are used to control the box temperature,
The water temperature and door temperature make the temperature of the studio with high precision and little fluctuation. (air jacket type
It is a double probe, which controls the temperature of the box and the door separately)
Light touch adjustment switch, light and flexible. The displayed and set parameters are
With digital display, each working status has LED indication
It has various protection functions such as over-temperature, water shortage, and gas cut-off to ensure the safety of the equipment.
fully operational
UV sterilization lamps are used to reduce contamination
Natural evaporation and humidification to maintain a better humidity in the studio