Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Catalyst FH100M Pump, 4-Channel, 6-Roller; 400 rpm, 115/230 V, Cole-Parmer (CAT#: STEM-DS-0304-LC)

Highlights

All operational parameters are clearly displayed on the multi-line LCD
Multiple programmable dispensing mode inlcude dispensing in volume, time, or copy modes
Convenient, automatic dispensing is achieved via programmed delay between cycles

Cat Number: STEM-DS-0304-LC

Application: Metering and dispensing applications

Model: 77724-00

Add to Cart



Description

The Catalyst Pump manufactured by Cole-Parmer is designed for metering and dispensing applications. The pump allows for remote control of speed, pumping direction, start/stop, and prime/purge. There are three operating modes including dispensing by volume, time, or copy.

Specification

Control Type: Variable-Speed Digital
Min RPM: 4
Max RPM: 400
Number of Channels: 4
Max Flow Rate (mL/min): 280
Min Flow Rate (mL/min): 0.21
Max Flow Rate Per Channel (mL/min): 280
Min Flow Rate Per Channel (mL/min): 0.21
Drive: Catalyst Digital Variable-Speed
Pump Head: Cartridge
Tubing sizes accepted: Precision two-stop links: 0.8, 1.6, 3.2, 4.8, 6.4 mm ID
Drive IP rating: IP 31
Power (VAC): 90 to 260
Number of Rollers: 6
Duty Cycle: Continuous
Power (amps): 1.6A at 115v; 1.9A at 230v
Power (Hz): 50/60
Width (in): 11
Height (in): 6
Length (in): 18
Width (cm): 27.9
Height (cm): 15.2
Length (cm): 45.7
Open-Head Sensor: No
Housing Material: ABS Plastic and Aluminum
Remote Inputs: 0 to 20 mA, 4 to 20 mA, 0 to 10 V; start/stop, direction, and prime via contact closure

Features

All operational parameters are clearly displayed on the multi-line LCD
Multiple programmable dispensing mode inlcude dispensing in volume, time, or copy modes
Convenient, automatic dispensing is achieved via programmed delay between cycles
Integral pump head enables tubing to be changed in less than 30 seconds — tubing occlusion is automatic when pump head is closed
Pump head is compatible with various tubing sizes for a wide flow range
Interlock switch powers unit down when pump head is opened for changing tubing
Programmable in seven languages for easy and intuitive setting
Calibrate the pump system under application conditions to improve system accuracy. The calibration is stored in memory, one calibration value for one tubing size
Fully assembled, integrated pump and drive systems reduce setup time

Related Products

Allegro™ I Peristaltic Pump System, Flow Rates Up To 1500 ml/min, KD Scientific (CAT#: STEM-DS-0040-LSY)
Allegro™ III Peristaltic Pump System, Flow Rates Up To 2000 ml/min, KD Scientific (CAT#: STEM-DS-0042-LSY)