DNP-Y Series Electric Thermostatic Incubator, 400W, Working Chamber Size 500×500×650 mm, Dimensions 645×595×940 mm, Shanghai Jing Hong Laboratory Instrument Co., Ltd (CAT#: STEM-GLE-0107-LGH)

Highlights

Programmable LCD controller is adopted.
Fixed value /30 segments can be set to run two modes, each segment timing up to 99 hours and 59 minutes.

Cat Number: STEM-GLE-0107-LGH

Application: For colleges and universities, medicine, biology, agriculture, scientific research departments for the storage of bacteria, biological cultivation, is a necessary equipment for scientific research laboratory.

Model: DNP-9162Y

Add to Cart



Description

DNP-Y Series Electric Thermostatic Incubator, DNP-9162Y, Shanghai Jing Hong Laboratory Instrument Co.,Ltd
1. Intelligent temperature controller is based microprocessor with PID parameters controlling function.Digital display of set and actual temperatures. High temperature controlling accuracy and reliability. With timing function, the maximum time is set to 9999 minutes.
2. Internal and external double door structure, small temperature fluctuation. The inner door adopts full-toughened glass door. Open the outer door to observe the situation in the box without affecting the temperature in the box.
3. Stainless steel inner bladder, four corners of the semi-arc easy to clean.
4. With overtemperature alarm system, to ensure the safe operation of equipment without accidents.
5. GNP model for water jacket heating mode, with uniform temperature and power can still maintain a long time of constant temperature advantages.
6. Can be equipped with embedded printer or RS-485 interface, used to connect the printer or computer, convenient record temperature parameters change. (optional)
7. Programmable LCD touch screen controller, can set multi-section program control, a variety of parameters on one screen display, simple operation, convenient program editing. (optional)
8. Can be installed SMS monitoring alarm system. When the user is not on site and the equipment fails, the system collects the fault signal in time and sends it to the mobile phone of the designated receiver in the first time through SMS to ensure that the fault is eliminated in time and the test is resumed to avoid accidental loss. (optional)

Specification

Power supply voltage: 220V 50HZ
Temperature control range (℃): RT+5~65℃
Temperature resolution: 0.1 ℃
Temperature fluctuatin: ±0.5℃
Operating ambient temperature: 5~30℃
Consumed power: 400W
Volume: 160L
Working chamber size (mm): 500×500×650
Dimensions (mm): 645×595×940
Carrier bracket (standard): 2

Features

Programmable LCD controller is adopted.
Fixed value /30 segments can be set to run two modes, each segment timing up to 99 hours and 59 minutes.