Monitoring Capabilities
Neonatal, pediatric and adult applications
Dimensions
Height: 8.5 in ( 215 mm)
Width: 11.9 in (301 mm)
Depth: 5.2 in (131 mm)
Weight: with out battery 7.32 lbs. (3.32 kg)
ECG
Available leads
3-lead set Leads: I, II, III
5-lead set Leads: I, II, III, aVR, aVL, aVF, V
6-lead set Leads: I, II, III, aVR, aVL, aVF, V, V+
Measuring range 15 to 300 bpm
Accuracy ± 5 bpm or ± 2% (whichever is greater)
Frequency range (± 3 db) 0.5 Hz to 28 Hz (50 Hz)
0.5 Hz to 40 Hz (60 Hz)
Filter Frequency 50 to 60 Hz
QRS Detection Range
Alarms User-selectable upper and lower limits
Pacer detection Leads: I, II, or III
Amplitude: ± 5 to ± 700 mV
Separation between pulses: 30 msec
Width (dp): 0.1 to 2.0 msec
Accessories 3-, 5- or 6-lead electrode set
Dual Lead ST Analysis
Refer to ST datasheet 9049456
Respiration
Sensing lead II
Measuring method Impedance pneumography
Auxiliary current 10μA for any active electrode
Detection threshold 0.15 to 4.0 in manual mode (user adjustment)
Adult and pediatric: 0.20 to 10.5 in auto mode (automatic adjustment)
Neonatal: 0.20 to 1.5 in auto mode (automatic adjustment)
Measuring range 0 to 155 breaths/min
Accuracy ± 1 l/min or ± 2% (whichever is greater)
Alarms User-selectable upper and lower respiration rate
Pulse Oximetry (SpO2)
Displayed parameters Saturation (fraction of oxyhemoglobin to functional hemoglobin) and pulse (rate and curve)
Measuring method Absorption spectrophotometry
Pulse 15 to 300 bpm
Accuracy SpO2: 0 to 69% not specified
SpO2: 70 to 100% ± 2% (except ± 3% when using Nellcor® DS-100A and ± 3.5% when using Masimo® LNOP-Ear)
Saturation accuracy increases by ± 1 digit for neonates
Pulse: ± 3 bpm or ± 3% (whichever is less)
Alarms User-selectable upper and lower limits for SpO2 and pulse
Accessories Dräger Medical-approved Masimo and Nellcor sensors
Temperature
Displayed parameters Absolute temperature
Measuring range 0 to 50°C
Accuracy Probe: ± 0.1°C
System: ± 0.2°C
Alarms User-selectable upper and lower limits
Accessories Dräger Medical-approved core and skin probes
Noninvasive Blood Pressure (NBP)
Displayed parameters Systolic, mean and diastolic pressures
Measuring method Oscillometric utilizing step deflation
Modes of operation
Manual (single measurement) interval or continuous (5 minutes)
Interval times Off, 2, 2.5, 3, 5 (increments of 5),
30, 45, 60, 120, 180, 240 minutes
Measuring range (default)
Adult (Adult 270 mmHg) (Adult 180 mmHg)
Heart rate 30 to 240 bpm 30 to 240 bpm
Systolic 30 to 250 mmHg 30 to 170 mmHg
Mean 20 to 230 mmHg 20 to 150 mmHg
Diastolic 10 to 210 mmHg 10 to 130 mmHg
Pediatric (Pediatric 180 mmHg) (Pediatric 140 mmHg)
Heart rate 30 to 240 bpm 30 to 240 bpm
Systolic 30 to 170 mmHg 30 to 130 mmHg
Mean 20 to 150 mmHg 20 to 110 mmHg
Diastolic 10 to 130 mmHg 10 to 130 mmHg
Neonatal (Neonatal 140 mmHg) (Neonatal 90 mmHg)
Heart rate 30 to 240 bpm 30 to 240 bpm
Systolic 30 to 130 mmHg 30 to 80 mmHg
Mean 20 to 110 mmHg 20 to 70 mmHg
Diastolic 10 to 100 mmHg 10 to 60 mmHg
Cuff pressure
Default inflation pressure Adult (270): 180 mmHg ± 5 mmHg
Pediatric (180): 130 mmHg ± 5 mmHg
Neonatal (140): 110 mmHg ± 5 mmHg
Adult (180): 130 mmHg ± 5 mmHg
Pediatric (140): 110 mmHg ± 5 mmHg
Neonatal (90): 80 mmHg ± 5 mmHg
Inflation pressure after a valid measurement (± 5 mmHg) Adult (270): Systolic + 25 mmHg
Pediatric (180): Systolic + 25 mmHg
Neonatal (140): Systolic + 30 mmHg
Adult (180): Systolic + 25 mmHg
Pediatric (140): Systolic + 30 mmHg
Neonatal (90): Systolic + 20 mmHg
Maximum inflation pressure Adult (270): 265 mmHg ± 5 mmHg
Pediatric (180): 180 mmHg ± 5 mmHg
Neonatal (140): 142 mmHg ± 5 mmHg
Adult (180): 180 mmHg ± 5 mmHg
Pediatric (140): 142 mmHg ± 5 mmHg
Neonatal (90): 80 mmHg ± 5 mmHg
Minimum inflation pressure Adult (270): 110 mmHg ± 5 mmHg
Adult (180): 90 mmHg ± 5 mmHg
Pediatric (180): 90 mmHg ± 5 mmHg
Pediatric (140): 70 mmHg ± 5 mmHg
Neonatal (both): 70 mmHg ± 5 mmHg
Connector Quick-release connector with single airway