Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

EDUF Systems, Maximum Operating Pressure At Element Inlet 60 PSIG, Synder Filtration (CAT#: STEM-GMAE-3086-LGZ)

Highlights

1. Integral bag filter reduces cost and floor space is saved.
2. CIP system: individual components are cleaned while the rest of the system remains online.
3. The CIP circuit has a bag filter device.

Cat Number: STEM-GMAE-3086-LGZ

Application: To guarantee optimal performance for your paint process.

Model: EDUF Systems

Add to Cart



Description

Synder filter offers a complete line of membrane products for the ECoat industry. In addition to our specially designed v-Series elements, which are ideal for any cathodic paint bath, we also offer custom Electrodeposition Ultrafiltration Systems (EDUF) to ensure optimum performance of your paint bath process. This quality product is achieved through a collaborative effort between our engineers and customers. Synder proudly owns the majority of North America's automotive system installations. Standard Modular System Parts: Housing Vessel, Housing Flow Meters, Stainless Steel Ball valves, Butterfly Valves, PVC Ball Valves, Gauges/Isolator, STANDARD CIP SYSTEM PARTS, CIP Pump, One/Two Point Temperature Switch, Cooling Coil, CIP Tank Heater, CIP Flow Meter.

Specification

Operational Parameters and Limitations for Electrodeposition Systems
Maximum operating pressure at element inlet: 60 PSIG
Maximum operating pressure at element outlet: 40 PSIG
Minimum operating pressure at element outlet: 5 PSIG
Minimum pressure drop per element at 70 GPM/element: 20 PSIG
Design pressure drop per element at 70 GPM/element: 25 PSIG
Maximum pressure drop per element at 70 GPM/element: 35 PSIG
Minimum feed rate per V62-7647.5 inch element: 65 GPM
Design feed rate per V62-7647.5 inch element: 70 GPM

Maximum operating temperature/cleaning
(Schedule 80 PVC piped EDUF System): 120° F @ 50 PSI
(Stainless Steel / CPVC piped EDUF System): 140° F @ 110 PSI

Maximum operating temperature/paint – per paint manufacturer’s specifications
Maximum pressure at permeate outlet: 5 PSIG
Recommended cleaning pressure profiles: 25 – 30 psi inlet pressure
(Note: all valves 100% open): 0 – 5 psi outlet pressure
pH range/cleaning: 2.0 – 12.0 @ 110° F; 4.5 – 11.0 @ 120° F

Features

1. Integral bag filter reduces cost and floor space is saved.
2. CIP system: individual components are cleaned while the rest of the system remains online.
3. The CIP circuit has a bag filter device.
4. The housing is stainless steel.
5. Stainless steel top and bottom covers are standard.
6. After sales support: We will be there to monitor and optimize system performance.

Related Products

Ultrafiltration & Microfiltration Systems, Stainless Steel, Synder Filtration(CAT#-STEM-GMAE-3082-LGZ)
Nanofiltration & Reverse Osmosis Systems, Automated Flow Control, Synder Filtration(CAT#-STEM-GMAE-3083-LGZ)
Sanitary Systems, Stainless Steel Valves, Synder Filtration(CAT#-STEM-GMAE-3084-LGZ)
Anode Cell Current Monitoring System, Analog CMS, Synder Filtration(CAT#-STEM-GMAE-3085-LGZ)
Anolyte Recirculation System, Conductivity Controller And Sensor, Synder Filtration(CAT#-STEM-GMAE-3087-LGZ)
Advertisement