Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Fluke Biomedical Index II 2 SpO2 Simulator/TESTED In Irvine, CA, USA, Fluke biotechnology & life science (CAT#: STEM-CTEPO-1170-YJL)

Highlights

Small, portable and lightweight
Large, easy to read LCD display
Rechargeable battery lasts 10 hours minimum

Cat Number: STEM-CTEPO-1170-YJL

Application: For testing

Model: Index II 2 SpO2

Add to Cart



Description

Fluke Biomedical Index II 2 SpO2 Simulator/TESTED In Irvine, CA, USA, model Index II 2 SpO2 is manufactured by Fluke biotechnology & life science.
The SPOT Light pulse oximeter tester is a lightweight and easy-to-use SpO2 functional tester. Preset programs test any combination of saturation, heart rate, perfusion, transmission, artifact noise, and R-curve in 15 seconds or less.

Specification

Condition: Used
Display: 2 1/4 in x 1 1/2 in LCD display
Size (WxDxH): 4.8 in x 3.8 in x 1.9 in (12.2 cm x 9.7 cm x 4.8 cm)
Weight: 8.8 oz.
Type: Rechargeable Lithium-Ion
Charge Time: Approximately two hours
Operating Duration: Approximately ten hours minimum
Input Voltage: 100 V ac to 240 V ac
Input Frequency: 50/60 Hz
Input Current: 0.5 A (rms)
Output Voltage: 6 V dc
Operating Temperature: 32 ºF to 95 ºF (0 ºC to 35 ºC)
Storage Temperature: -31 ºF to 122 ºF (-35 ºC to 50 ºC)
Operating Humidity: 20- 80% RH (non-condensing)
SpO2 Saturation: 70%, 75%, 80 %, 85 %, 90 %, 95 %, 97 %, 98 %, 99 % and 100 %
Heart Rate: 30, 40, 60, 65, 80, 100, 120, 140, 150, 180 and 240 BPM
Perfusion Rate: 0.2 %, 2 % and 10 %
Transmission Level (finger): Dark/Thick, Normal and Light/Thin
Artifacts: Respiration or ambient light (50 Hz or 60 Hz)

Features

Small, portable and lightweight
Large, easy to read LCD display
Rechargeable battery lasts 10 hours minimum
Signal strength indicator
SpO2 Saturation: 70%, 75%, 80 %, 85 %, 90 %, 95 %, 97 %, 98 %, 99 % and 100 %
Heart rate: 30, 40, 60, 65, 80, 100, 120, 140, 150, 180 and 240 BPM
Perfusion: 0.2 %, 2 % and 10 %
Transmission: dark/thick, normal and light/thin
Artifacts: respiration and ambient light
R-curves: Nonin, Masimo, Nellcor, Nihon Kohden, Mindray, GE, Philips, BCI

Related Products

GE Vivid 7 Dimension In Sweet Grass, MT, USA (CAT#: STEM-CTEPO-1171-YJL)
GE Venue In Gilbert, IA, USA (CAT#: STEM-CTEPO-1172-YJL)
GE M12L In Temecula, CA, USA (CAT#: STEM-CTEPO-1173-YJL)
GE BE9C In Temecula, CA, USA (CAT#: STEM-CTEPO-1174-YJL)
GE PORTABLE MAC 800 RESTING ECG System In Temecula, CA, USA (CAT#: STEM-CTEPO-1175-YJL)
GE Logiq 7 Ultrasound Machine In Temecula, CA, USA (CAT#: STEM-CTEPO-1176-YJL)
Advertisement