Fluke Calibration 5615-9-P In Rochester, NY, USA, model 5615-9-P is manufactured by Fluke power calibration instruments. The Fluke Calibration 56159P Secondary Standard PRT Probe with INFO-CON for 1523/1524, 9 in. x.188 in., -200 °C to 420 °C, 6 ft. Lead has an Inconel 600 sheath that is 229 mm (9 in.) long and 4.76 mm (0.188 in.) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C.
Specification
Condition: Used Termination: INFO-CON for Models 1523 and 1524 Temperature range: -200 °C to 420 °C Nominal resistance at 0 °C: 100 Ohm ± 0.10 Ohm Temperature coefficient 0.0039250 Ohm/Ohm/°C Accuracy (includes calibration and 100 hr drift (k=2)): ±0.024 °C at -200 °C; ±0.012 °C at 0 °C; ±0.035 °C at 420 °CC Short-term repeatability (three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)): ±0.009 °C at 0.010 °C Drift (After 100 hrs at max temp, 95 % confidence (k=2)): ±0.007 °C at 0.010 °C Sensor length: 28 mm (1.1 in.) Sensor location: 6.9 mm ± 3.3 mm from tip (0.27 in. ± 0.13 in.) Sheath dimensions: 229 mm x 4.76 mm (9.0 in. x 0.188 in.) Sheath diameter tolerance: ±0.127 mm (±0.005 in.) Sheath material: Inconel 600 Minimum insulation resistance: 1000 MOhm at 23 °C Transition junction temperature range (temperatures outside this range will cause irreparable damage; for best performance, transition junction should not be too hot to touch): -50 °C to 200 °C Transition junction dimensions: 71 mm x 13 mm dia (2.8 in. x 0.5 in.) Maximum immersion length: 178 mm (7 in.) Response time (Per ASTM E 644): 9 seconds typical Self heating (in 0 °C bath): 50 mW/°C Lead-wire cable type: PTFE insulated with PTFE jacket, 22 AWG Lead-wire length: 183 cm (72 in. or 6 ft.) Lead-wire temperature range: -50 °C to 200 °C Calibration: NVLAP-accredited calibration included, lab code 200706-0
Fluke Fleible Ac Current ProbeBirmingham, AL (CAT#: STEM-GLEPO-1004-YJL) Fluke Corporation 80PK-22 In Orlando, FL, USA (CAT#: STEM-GLEPO-1064-YJL) Fluke Corporation 80PK-11 In Orlando, FL, USA (CAT#: STEM-GLEPO-1065-YJL) Hart Scientific (Fluke) Calibration 5627A-9 Industrial PRT Temperature Probe, 9" In Bloomfield, CT, USA (CAT#: STEM-GLEPO-1075-YJL) GE E8CS In Temecula, CA, USA (CAT#: STEM-GLEPO-1116-YJL) GE 9L Model 5131433 Linear Array 8-3 MHz Vascular Probe in Temecula, CA, USA (CAT#: STEM-GLEPO-1117-YJL) GE 5440423 3-Probe Port Box In Kaysville, UT, USA (CAT#: STEM-GLEPO-1173-YJL) Instek/GW GHT-205 In Farmingdale, NJ, USA (CAT#: STEM-GLEPO-1415-YJL)