Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

GeneQ Thermal Cycler TC-18/H(b), Bioer Technology (CAT#: STEM-PCRE-0160-LKN)

Highlights

The Gene Q Thermal Cycler is a thermoelectric cooling thermal cycler. It features:
Reliable and stable operation, because the thermoelectric module is manufactured via the
U.S. ITI's thermoelectric cooling technique and the Japanese quality management model;

Cat Number: STEM-PCRE-0160-LKN

Application: Nucleic acid amplification.

Model: TC-18/H(b)

Add to Cart



Description

GeneQ Thermal Cycler TC-18/H(b) from Bioer Technology features superior performance, compact structure, friendly interface, reliable results for all. Especially in the heating speed, temperature control accuracy, uniformity and module, GeneQ shows the excellent performance.

Specification

Sample capacity: 18*0.5ml
Temp. range: 4.0°C-99.9°C
Max. heating rate: ≥4°C/sec
Max. colling rate: ≥3°C/sec
Block temp. uniformity: ≤±0.2°C
Block temp. accuracy: ≤±0.2°C
Adjustability of hot lid press: YES
Temp. control modes: BLOCK, TUBE
Display: 320*240 LCD, 3.8 inch
Program storage: 100 files
Max. segments: 5
Max. program steps: 16
Max. cycles: 99
Power supply: AC220V, 50Hz, 600W

Features

The Gene Q Thermal Cycler is a thermoelectric cooling thermal cycler. It features:
Reliable and stable operation, because the thermoelectric module is manufactured via the
U.S. ITI's thermoelectric cooling technique and the Japanese quality management model;
High heating/cooling (heating rate ≥5.0°C/sec., and cooling rate ≥4.0°C/sec.), which greatly reduces experimental time;
Automatic temperature ramp control, which allows different heating/cooling ramp settings so that the device can emulate other thermal cycler's temperature control process;
Automatic temperature and time increments/decrements during cycling program execution, optimizing the PCR amplification conditions;
Automatic link among files, allowing a complex PCR amplification program to be executed;
The soak mode at a temperature up to 4°C without human interference, after normal cycling program execution;
Instant inspection of total execution time and remaining execution time;
Optional heated lid, preventing the sample in a centrifugal tube from evaporation, which makes paraffin oil unnecessary and operation more convenient, and reduces the sample processing time;
Auto-restart in case of power failure, restoring the data before interrupting and continuing to perform the previously interrupted program.

Related Products

Hema Gradient PCR Thermal Cycler 9700/9600, Hema Medical Instrument (CAT#: STEM-PCRE-0161-LKN)
TE(peltier)Cooling PCR Thermocycler 3200/1600, Hema Medical Instrument (CAT#: STEM-PCRE-0162-LKN)
Advertisement