HP Agilent 1050 series HPLC (DAD/MWD), 200-315 nm, HP Agilent (CAT#: STEM-CPO-0048-YJL)

Highlights

Modular design
Diode Array Detector or Multiple Wavelength Detector
User-friendly interface

Cat Number: STEM-CPO-0048-YJL

Application: For HPLC analysis

Model: 1050 (DAD/MWD)

Add to Cart



Description

HP Agilent 1050 series HPLC (DAD/MWD), 200-315 nm, model 1050 (DAD/MWD), is manufactured by HP Agilent. The HP Agilent 1050 Series HPLC is a series of HPLC components based on a modular design that allows laboratories to customize a system to suit the individual demands of their applications. GMI offers both the HP Agilent 1050 DAD system and MWD system.
The two HP 1050 HPLC systems carry either the 1050 Diode Array Detector (DAD) or the Multiple Wavelength Detector (MWD). The DAD is similar to the MWD, and has the same hardware except for their keyboard and firmware. Basically the MWD, the DAD operates with added spectra capabilities and is controlled by the HPLC DOS compatible data analysis software.
Both HPLC modules are equipped with an optical system and electronic circuitry for acquisition and processing of absorbance data. Controlled by a user-friendly interface, the 1050 systems allow the operator to define parameters and present analytical information.
The Agilent 1050 DAD and MWD systems make it possible to optimize the signal-to-noise and spectral resolution. The flow cell and slit are separate. Flow cells with different path lengths and slit assemblies with different optical slit widths are available. Other features include flow cell and slit assemblies, a deuterium lamp, a heat exchanger device, a shutter assembly, and a leak sensor system.

Specification

Condition: Certified Pre-Owned
Safety: Class I
Noise
Radiation: 200-315 nm
Common Electronics: Main processor, remote control, Firmware Boards (FIM, SFW), Fluorescent Indicator module,
Externa Contacts, power supplies, communication interfaces
Common Functions: Display handlingKeyboard polling; Remote control input and output; Leak sensing; Option interfacing; Time programming; Method storage; Module configuration; Memory switching; 32 kbyte RAM with battery back-up for parameter storage
Timer: 3 programmable
Signals: Shut down, power on, ready, prepare, start request, start, stop

Features

Modular design
Diode Array Detector or Multiple Wavelength Detector
User-friendly interface
Optimized signal-to-noise and spectral resolution
Flow cell and slit assemblies
Deuterium lamp

Related Products

Agilent 1100 Binary DAD HPLC System, 0.001–5 ml/min, HP Agilent (CAT#: STEM-CPO-0039-YJL)
Agilent 1100 LC MSD Model G1946D Mass Spectrometer, 2-3000 amu, HP Agilent (CAT#: STEM-CPO-0040-YJL)
Agilent 1100 Quaternary DAD HPLC System, HP Agilent (CAT#: STEM-CPO-0041-YJL)
Agilent 1200 Binary DAD HPLC System, 0.001 – 5 ml/min, HP Agilent (CAT#: STEM-CPO-0042-YJL)
Agilent 1200 Quat MWD System, 0.001 – 10 ml/min, HP Agilent (CAT#: STEM-CPO-0043-YJL)
Agilent 1200 Quat MWD System, 190–600 nm, HP Agilent (CAT#: STEM-CPO-0044-YJL)
Advertisement