The manufacturer of the ICS-1100 Ion Chromatography System is Dionex. The Dionex ICS-1100 Ion Chromatography System is a powerful and versatile instrument designed for high-performance analysis of ionic compounds in various sample types. With its advanced ion chromatography technology, the ICS-1100 can effectively separate, identify, and quantify anions, cations, and polar molecules in complex mixtures with exceptional accuracy and precision. This system comes equipped with a variety of features that enable efficient and reliable analysis, including a state-of-the-art eluent generation system, which eliminates the need for handling and storing hazardous chemicals. The ICS-1100 also features a high-pressure gradient pump, a temperature-controlled column compartment, and a wide range of detector options, including conductivity, UV-vis, and amperometric detectors.
Specification
Condition: Pre-owned Dimensions (h × w × d): 56.1 cm × 22.4 cm × 53.3 cm (22.1 × 8.8 × 21 in.) Weight: 24.5 kg (54 lb) Power Requirements: 100–240 V ac, 50-60 Hz, autoranging Operating Temperature: 4–40 °C (40–104 °F); cold-room-compatible (4° C) as long as system power remains on Operating Humidity Range: 5–95% relative, noncondensing Leak Detection: Built-in, optical sensor
Analytical Pump and Fluidics: Type: Serial dual-reciprocating pistons, microprocessor-controlled constant stroke, variable speed Construction: Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of pH 0–14 and reversed-phase solvents Pump Operating Pressure: 0–35 MPa (0–5000 psi) Flow Rate Range: 0.00–5.00 mL/min in 0.01 increments without changing pump heads Flow Precision: < 0.1%, typically Flow Accuracy: < 0.1%, typically Pressure Ripple: < 1.0% at 13.8 MPa (2000 psi) and 1.0 mL/min Eluent On-Off Valve: Standard Piston Seal Wash: Dual-pump head, wash can be continuous when connected to rinse solution supply Pressure Alarm Limits: Upper limit 0–35 MPa or 0–5000 psi in one unit (MPa or psi) increments; lower limit can be set up to one unit lower than upper limit Vacuum Degas: Yes, optional, automatic control Eluent Bottles: Polypropylene, up to 4 L volume Eluent Bottle Pressure: Not required Injection Valve: 6-port, 2-position Rheodyne valve, electrically activated Columns Supported: 2, 3, 4, and 5 mm i.d.; maximum length 250 mm analytical column with 50 mm guard column
Features
Refurbished to meet manufacturer's specification In excellent condition Thoroughly cleaned Certified with warranty