IL ACL 10000 Coagulation Analyzer, 192 tests/hour, model ACL 10000, is manufactured by IL. Belonging to the ACL family of Coagulation Analyzers from Instrumentation Laboratory, the ACL 10000 boasts 30 assays with a maximum throughput of 190 tests per hour. The system is easy to navigate, robust and well respected in the hemostasis marketplace worldwide. Coagulation analysis detects abnormalities in the components required to complete normal blood clotting. Analysis is divided into two elements; the measurement of clot timing and if the timing is abnormal, a deeper analysis to determine which factors affecting normal coagulation are deficient. Clotting disorders are either classified as Hypocoagulability, a disorder of impaired or slowed coagulation and Hypercoagulability, a disorder of unnaturally fast clotting time or manner. Hypocoagulability can result in hemorrhage or other acquired coagulation disorders such as Hemophilia while Hypercoagulability can cause unnatural clots in arteries and other vessels which could result in severe organ damage or possibly death. A balance normally exists between the factors that stimulate formation of thrombin and forces acting to delay thrombin formation. This balance maintains circulating blood as a fluid. When injury occurs or blood is removed from a blood vessel, this balance is upset and coagulation begins. Coagulation may occur unexpectedly and internally. Symptoms for coagulation disorders are spontaneous bruising, prolonged bleeding, abnormal nosebleeds, heavy menstrual flow or gastrointestinal bleeding.
Specification
Condition: Certified Pre-Owned Auto Dilution: Yes Auto Sample Handling: Yes CLIA Complexity: Moderate Configuration: Bench Top Depth: 60 cm (24 in) Direct Sample (STAT): Yes Height: 60 cm (24 in) I.N.R.: Yes Manufacturer: Instrumentation Laboratory Maximum Throughput: 192 tests/hour Number of Assays: 30 On-Board Refrigeration: Yes Optical Source: Halogen Lamp LED Optical System: Filter Photometric (FP) Mono-chromatic Other Features: Posseses rotor transport and rotor arm Patient Sample Capacity: 40 Point Of Care: No Power Supply: 110V-220V Reagent Capacity: 12 Reagent System: Open Reagent Type: Liquid Sample Cycle Time: 0 (sec) Sample Input Closed Tube: No Sample Input Type: Sample Cups Sample Tubes Sample Size Max: 100 μL Sample Size Min: 3 μL Sample Types: Plasma Series: ACL Weight: 63 kg (139 lb) Width: 100 cm (39 in)