Interrogating viral capsid assembly by ion mobility–mass spectrometry (CAT#: STEM-ST-0135-LJX)

Introduction

Most proteins fulfil their function as part of large protein complexes. Surprisingly, little is known about the pathways and regulation of protein assembly. Several viral coat proteins can spontaneously assemble into capsids in vitro with morphologies identical to the native virion and thus resemble ideal model systems for studying protein complex formation. Even for these systems, the mechanism for self-assembly is still poorly understood, although it is generally thought that smaller oligomeric structures form key intermediates. This assembly nucleus and larger viral assembly intermediates are typically low abundant and difficult to monitor. Here, we characterised small oligomers of Hepatitis B virus (HBV) and norovirus under equilibrium conditions using native ion mobility mass spectrometry.




Principle

Ion mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.

Applications

For studying the gas phase ion structure
For detecting the chemical warfare agents and explosives
For the analysis of proteins, peptides, drug-like molecules and nano particles
For monitoring isomeric reaction intermediates and probe their kinetics
For proteomics and pharmaceutical analysis

Procedure

1. Add sample
2. The ions in the sample are separated in the ion mobility spectrometer
3. The separated ions are introduced into the mass analyzer for detection
4. Store the detection results

Materials

• Sample Type:
Hepatitis B virus

Notes

1. Ion mobility spectrometry is also a very fast technique, making it suitable for high-throughput applications. The entire analysis can be completed in just a few minutes.
2. The method is extremely sensitive and able to detect trace amounts of contaminants that other spectrometry methods would miss.
3. The effective separation of analytes achieved with this method makes it widely applicable in the analysis of complex samples such as in proteomics and metabolomics.