Isolated Microvascular Pressure Myography System, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1012-YJL)

Highlights

Compared with other vascular perfusion equipment, the in vitro microvascular pressure diameter measurement system can measure more vascular parameters. Using MyoVIEW in vitro blood vessel analysis software, you can collect and record blood vessel wall thickness, blood vessel lumen internal and external diameters, blood vessel transmural pressure and other related parameters, such as shear force and vascular resistance. Compared with traditional perfusion systems, this system provides users with simulated physiological environmental conditions, allowing for a more comprehensive and direct analysis of vascular physiological functions.

Cat Number: STEM-LEAR-1012-YJL

Application: Used to study the physiological functions of small arteries, veins and other blood vessels

Model: 114P

Add to Cart



Description

Isolated Microvascular Pressure Myography System, model 114P is manufactured by RWD Life Science Co.,LTD
The in vitro microvascular pressure myography system-114P is used to study the physiological functions of microarteries, veins and other blood vessels. Simulate the physiological environment in the body in vitro, and study the pharmacology of drugs and the mechanism of action of other vasoactive compounds under simulated physiological conditions. An isolated microvessel sample is tied to two hollow glass cannulas, and the physiological pressure and temperature of the blood vessel are adjusted through the host settings; the buffer solution flows through the lumen of the blood vessel to simulate the physiological environment of the blood vessel. Study vascular myogenic responses, flow-mediated vasodilation, and drug activity testing under simulated physiological conditions.
The center of the bathtub is made of medical-grade acid-resistant stainless steel, which is acid-resistant and corrosion-resistant, easy to clean, and has a long service life.

Specification

Measurable sample: minimum 30 microns, maximum 10 mm

Features

Compared with other vascular perfusion equipment, the in vitro microvascular pressure diameter measurement system can measure more vascular parameters. Using MyoVIEW in vitro blood vessel analysis software, you can collect and record blood vessel wall thickness, blood vessel lumen internal and external diameters, blood vessel transmural pressure and other related parameters, such as shear force and vascular resistance. Compared with traditional perfusion systems, this system provides users with simulated physiological environmental conditions, allowing for a more comprehensive and direct analysis of vascular physiological functions.

Related Products

Isolated Tissue Perfusion System, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1013-YJL)
Isolated Muscle Strip Tension Measurement System, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1014-YJL)
Automatic Buffer Dispenser, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1015-YJL)
Micro Flow Meter, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1016-YJL)
Electrical Stimulator – CS8, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1017-YJL)
Constant Voltage Similator – CS4, RWD Life Science Co.,LTD (CAT#: STEM-LEAR-1018-YJL)
Advertisement