Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

OPTIMA 5 MS Accent Gas Chromatography Capillary Column, Inner Diameter 0.32 mm, Film Thickness 0.50 µm, Column Length 30 m, MN725813.30 (CAT#: STEM-C-2853-ZJF)

Highlights

5% Diphenyl - 95% Dimethylpolysiloxane MS Grade (USP G27/G36)
Suitable for: Trace sample detection with ion trap and MS detectors; meets basic inert compound requirements
Comparable Stationary Phases: DB-5, DB-5 MS, HP-5 MS, Ultra-2, Equity™-5, CP-Sil 8CB low bleed/MS, Rxi-5 MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX™5, MDN-5S, AT™-5 MS, VF-5 MS

Cat Number: STEM-C-2853-ZJF

Application: For precise separation and analysis of complex chemical mixtures.

Model: MN725813.30

Add to Cart



Description

Gas chromatography capillary columns are designed to provide exceptional separation performance for a wide range of complex chemical analyses. Utilizing advanced technology and high-quality stationary phases, these columns offer superior efficiency and reliability in various applications, including food safety, environmental monitoring, pharmaceutical research, and industrial chemical analysis. With a commitment to precision and durability, our capillary columns ensure accurate and reproducible results, making them an essential tool for any analytical laboratory.

Specification

Inner Diameter: 0.32 mm
Film Thickness: 0.50 µm
Column Length: 30 m

Features

5% Diphenyl - 95% Dimethylpolysiloxane MS Grade (USP G27/G36)
Suitable for: Trace sample detection with ion trap and MS detectors; meets basic inert compound requirements
Comparable Stationary Phases: DB-5, DB-5 MS, HP-5 MS, Ultra-2, Equity™-5, CP-Sil 8CB low bleed/MS, Rxi-5 MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX™5, MDN-5S, AT™-5 MS, VF-5 MS
Maximum Operating Temperature: 340℃/360℃; For film thickness >0.5 µm: Maximum operating temperature 320℃/340℃
Accent Columns: Ultra-low bleed columns with minimal background noise, enhancing analytical sensitivity

Related Products

OPTIMA 5 MS Accent Gas Chromatography Capillary Column, Inner Diameter 0.32 mm, Film Thickness 0.25 µm, Column Length 30 m, MN725811.30
OPTIMA 5 MS Accent Gas Chromatography Capillary Column, Inner Diameter 0.32 mm, Film Thickness 0.25 µm, Column Length 60 m, MN725811.60
OPTIMA 5 MS Accent Gas Chromatography Capillary Column, Inner Diameter 0.32 mm, Film Thickness 1.0 µm, Column Length 25 m, MN725812.25
OPTIMA 5 MS Accent Gas Chromatography Capillary Column, Inner Diameter 0.32 mm, Film Thickness 1.0 µm, Column Length 60 m, MN725812.60
Advertisement