Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Packard Cobra 5010 Gamma Counter Series, Detector Shield Thickness 18 mm, Packard Cobra (CAT#: STEM-AIAEPO-0155-LGZ)

Highlights

Available in four models
Fully automatic- cassette driven system
Fast throughput rates

Cat Number: STEM-AIAEPO-0155-LGZ

Application: For testing in the field of biology.

Model: Cobra 5010

Add to Cart



Description

The Packard Cobra II gamma counter is considered one of our core instruments. The series is available in single, five or ten detector configurations. All Cobra gamma counter models can count 12x75mm RIA tubes, 16x100mm and various smaller microtubes using an available adapter. (If you need help, please contact our expert technical team.)

All Cobra systems include LCD output, dot matrix printers, tube racks, protocol ID labels and operating manuals. Specific calculations include calibration curve display-, linear-, polynomial regression-, log-, logit-, 4pl-, automatic spline-, manual spline-, and cubic spline curve fitting algorithms.

Single detector models are available in 2-inch or 3-inch crystal configurations for research-grade capabilities. The system can accommodate pipes from 12mm to 16mm. GMI has the following models of the Packard Cobra range:

Packard Cobra Model 5002
Packard Cobra Model 5003
Packard Cobra Model 5005
Packard Cobra Model 5010

Our certification guarantees that all products meet the manufacturer's original specifications.

Packard Cobra Model 5002
This versatile model is ideal for research and everyday laboratory applications. System specifications include a single 2-inch sodium iodide (NaI) through-hole detector, 2000 KeV energy range and 750 sample capacity. The system includes a new LCD monitor, Epson printer and test tube cassettes. An optional instrument cart is also available. The Packard Cobra 5002 system is GMI certified, ensuring that original manufacturer specifications, including detector efficiency and crystal resolution, are maintained.

Packard Cobra Model 5003
The Cobra II 5003 is a true research grade gamma counter. System specifications include a 3-inch NaI through-hole crystal detector, 2000 KeV energy range and 750 sample capacity. This system is ideal for calculating low-energy activity and high-energy isotopes.

Packard Cobra Model 5005

The Cobra II 5005 is a multi-detector system with five 1.5-inch NaI through-hole detectors with an energy range up to 1000 KeV. With the ability to count 5 samples at a time, the 5005 is a suitable model for laboratories with high throughput requirements.

Packard Cobra Model 5010
The Cobra II 5010 is a 10 detector system that provides the highest throughput available. This model is capable of automatically counting up to 1000 RIA tubes. High-capacity systems, including the Model 5010, are ideal for use in large reference laboratories or research laboratories that can count large batches of short-lived isotopes, such as PET facilities.

Specification

Condition: certified pre-owned
Test Tube Size (Sample Specifications): Up to 14 mm x 106 mm
Power: 100-130/200-260 VAC
Frequency: 50/60 Hz
Device (Temperature Regulation): Automated gamma counter
Interface protocols (Data Processing): RS232C, optional second RS232C, Ethernet LAN adapter
Stat Capability (Plasma Sample): Yes
Yield/hr: 250 : 500
Warm-Up Time (Test Tube): Continuous power
Dimensions of Display (H x W x D): 71.1 cm x 68.6 cm x 81.3 cm (28 in. x 27 in. x 32 in.)
WEIGHT, kg (lb) (DISPLAY): 181.4 kg (400 lbs)
Detector (Scattered Light)
Characteristics (Image Storage): Through-hole
Efficiency, % (Gas Trap): >75
Detector Shield thickness: 18 mm
Number of Staining Posts: 5 or 10
Internal Calibration (Protocols): Continuous
Alternatives (Staining Stations): Yes
Display: SVGA CRT, printer
Data Processing: Integrated 586/133 PC RIA QC system
Reductions (Error): Optional
Algorithms (Detector): Linear, polynomial regression, loglogit, 4-PL, auto spline, manual spline, cubic spline
Calibration Curve Display (Detector): Yes
Calibration curve edit (Detector): Yes
User definable (Programs): 60
Energy Windows
Dual-label assay: Yes
Preset: I-125, Co-57, Cr-51
Adjustable (SASH): 15-2,000 keV
Other Attributes (Interference Compensation): RIA-QC data management system; coded assay for special assay protocols; spectral analyzer, 2″ or 3″ detector; software for microsphere. Meets requirements of CE 93 (IEC 61010-1, IEC 801-4, CISPR Pub. 22 class B), CSA, FCC, GS mark, and TUV. Pac

Features

Available in four models
Fully automatic- cassette driven system
Fast throughput rates
Stat capability

Related Products

Agilent 6890 Series GC Single Detector System, HP Agilent (CAT#-STEM-AIAEPO-0163-LGZ)
Agilent 6890N Gas Chromatograph, 28 × 31 × 16 cm, HP Agilent (CAT#-STEM-AIAEPO-0164-LGZ)
Hewlett Packard HP 5890 Series GC, Weight 90 lbs (41 kg), HP Agilent (CAT#-STEM-AIAEPO-0165-LGZ)
Hewlett Packard HP 5890 Series GC, Frequency 47.5 – 66 Hz, HP Agilent (CAT#-STEM-AIAEPO-0166-LGZ)
HP 5890 Series II Dual Detector II GC System I, HP Agilent (CAT#-STEM-AIAEPO-0167-LGZ)
HP 5890 Series II Single Detector GC System, HP Agilent (CAT#-STEM-AIAEPO-0168-LGZ)
Advertisement