The manufacturer of the PE 200 Series Micro Pump, Perkin Elmer is Perkin Elmer.
Refurbished Perkin Elmer Series 200 LC Micro Pump. (p/n LCPUMP3 & N2910500) The Series 200 Micro Pump is PerkinElmer's fifth generation LC solvent delivery system and has proven itself to be extremely reliable and rugged. With its low delay volume the Series 200 is ideal for narrowbore chromatography - or as a front-end to your LC/MS. The Series 200 Micro Pump offers superior flow rate precision (typically <0.1%), compositional accuracy (typically +/- 0.50%), and retention-time precision (typically <0.1%) for either isocratic or gradient separations.
The Series 200 Micro Pump has stand-alone capability or may be placed under full PC control as part of either a TotalChrom LC Plus system, a ThermoFinnigan XCalibur LC/MS system - or a Sciex Analyst LC/MS system.
The Series 200 MicroPump is available in isocratic or binary high pressure blending configurations.

Specification

Condition: Refurbished, Certified Pre-owned
Flow Rate Range: 1 µL/min – 3 mL/min
Flow Rate Increments: 1 µL/min from 0 to 0.999 mL/min; 0.01 to 3 mL/min
Flow Precision: 0.3% RSD (typical 0.1%) at 300µL/min water @ 1000 psi
Flow Accuracy: ±1% of setting at 300 µL/min and 1000 psi with water
Retention TimeReproducibility: < 0.3% RSD (typically < 0.1%)
Pressure Range: 0 to 6200 psi for the entire flow-rate range
Compositional Range: 0 to 100%, settable to 1%
Compositional Accuracy: Typically 0.5% from 10 to 90% up to 2 mL/min
Compositional Precision: Typically < 0.2% variation
Gradient Forms: Linear, convex and concave w/high pressure blender
Linearity: Within 1% from 10 to 90%
Program Steps: Step 0 (Equil) plus up to 20 solvent program steps. Battery-backed storage of up to 20 methods
: plus 1 edit method and 1 default method
Step Time: 0 to 999 minutes
Step Time increments: 0.1 min from 0 to 9.9 min; 1.0 min from 10 to 999 min
Timed Events: Two built-in independent momentary (2 second) contact closures
Events/Method: Max of 9
Event Increments: 0.1 min from 0 to 9.9 min; 1.0 min from 10 to 999 min

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty

Related Products

PE 862 Chromatography Interface, Perkin Elmer
PE NCI 900 Network Interface Box, Perkin Elmer
PE Nelson 500 Series IVM Interface Validation Module, Perkin Elmer
Advertisement