The manufacturer of the PE Series 200 UV/Vis Detector, Perkin Elmer is Perkin Elmer. Performance, reliability and ease of use are the criteria by which the Series 200 UV/Vis detector should be judged because those are the cornerstones on which it was designed and built. With over a decade of innovation and outstanding analytical performance to draw upon, the Series 200 UV/Vis is the successor to the industry-standard UV/Vis detector; the Model 785A. Making the best detector even better was not easy however, the Series 200 UV/Vis adds new features and benefits to an already impressive portfolio, making it the smart choice as your next HPLC detector.
Specification
Condition: Refurbished, Certified Pre-owned Wavelength range: 190-700 nm Bandwidth: 5 nm Wavelength accuracy: +/- 1 nm Optics: Dual beam Sensitivity Range: 0.0005 to 3.000 AUFS in 0.0001 increments from 0.0005 to 0.1, and 0.01 increments above 0.1 AUFS. Recorder output: 10 mV full scale for any selected range. Computer output: 1 V/AU, 0.5 V/AU, 0.2 V/AU (software control) Noise: < +/- 1 x 10 -5 AU, 210-280 nm, 1 sec. rise time, test flowcell. Drift: < 1 x 10 -4 AU/hour, after warm-up Light sources: Deuterium (190-360nm) or Tungsten (360-700nm) prefocused-no adjustment required on replacement. Leak detection: Heated thermistor sensor in glass envelope located in flow cell drip pan Display: Graphic LCD module 240 X 64 pixel. Series 200 standard Noise filter: Digitally controlled active filter with response (RSP) or peak width (PW) selectable from 0.02 to 5.0 seconds in 8 steps. Number of methods: 20 in battery backed memory Steps per method: 20 maximum; multiple simultaneous events may occur in any given step Method time: Up to 999.99 minutes per method Programmable functions from the front keypad or Turbochrom: Time, wavelength, response time, auto-zero, relay closures, method number, number of injections, (method execution via sequence) Scan: Stopped flow scan, scan speed selectable from 0.2 to 1.0 nm/sec External communications: RS-232 for control, down load of methods via Turbochrom and upload of chromatographic data. Max. Chromatographic data rate is 50 data points per second. Diagnostics: Self-testing as per software diagnostic standards Microprocessor: Motorola 68332
Features
Refurbished to meet manufacturer's specification In excellent condition Thoroughly cleaned Money back guarantee Certified with warranty
Related Products
PE Series 200 Mixer Valve, Perkin Elmer 785A UV/Vis Detector, Perkin Elmer Altus A-30 FL Detector, Perkin Elmer