Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Pharmacia Optical Unit UV-1 FPLC UV Detector, Pharmacia Fine Chemicals (CAT#: STEM-C-0249-LGZ)

Highlights

1. The detector is used for the monitoring of proteins, nucleic acids and other substances at 254, 280 or 405 nm.
2. The UV-1 is a flow-through dual beam column monitoring ideally suited for a wide range of chromatographic conditions.
3. Has a wide sensitivity range, measuring optical density from 0.0004 to 6.67 and transmittance from 0 to 100%.

Cat Number: STEM-C-0249-LGZ

Application: To monitor the absorbance or transmission of a flowing liquid.

Model: Monitor UV-1

Add to Cart



Description

The manufacturer of Pharmacia Optical Unit UV-1 FPLC UV Detector is Pharmacia Fine Chemicals. Model is Monitor UV-1. The Single Path Monitor UV-1 is a dual beam through UV absorbance meter that monitors UV absorption of flowing liquids at 254 nm, 280 nm, or 405 nm, equipped with a UV-1 control unit, optical unit, a 280 nm wavelength filter and A 280 nm converter and flow cell with optical path length of 3 mm or 10 mm.

Specification

Condition: used
Absorbance range: 0.01 to 2 AU
Dimensions (L x W x D): 18 x 14.5 x 7.5 cm
Weight: 1.6 kg
Power Supply: 100/120/220-230/240V, 50/60 Hz

Features

1. The detector is used for the monitoring of proteins, nucleic acids and other substances at 254, 280 or 405 nm.
2. The UV-1 is a flow-through dual beam column monitoring ideally suited for a wide range of chromatographic conditions.
3. Has a wide sensitivity range, measuring optical density from 0.0004 to 6.67 and transmittance from 0 to 100%.
4. Requires filter kit (not included).
5. Measure UV absorbance in the range of 0.01-2 absorbance units, 8 full scale sensitivity range. Results are expressed in AU or %T.
6. Simple wavelength change and interference filter.
7. The flow through the reference cell compensates for the background absorption shown by the solvent or buffer salts.
8. Linearity is better than +/- 3% to 2 AU at 254nm with flowing liquid.
9. Output: 0 to 10mV. Working temperature: 0 °C ~ 40 °C. Noise: 0.0004 AU (peak-to-peak with flowing liquid).

Related Products

Agilent 1100 Series - G1315B HPLC Diode Array Detector, Agilent Technologies(CAT#-STEM-C-0037-LGZ)
Agilent 1100 Series - G1321A HPLC Fluorescence Detector, Agilent Technologies(CAT#-STEM-C-0039-LGZ)
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector, Agilent Technologies(CAT#-STEM-C-0050-LGZ)
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector, Agilent Technologies(CAT#-STEM-C-0051-LGZ)
Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector, Agilent Technologies(CAT#-STEM-C-0066-LGZ)
Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector, Agilent Technologies(CAT#-STEM-C-0067-LGZ)
Advertisement