PL-GPC 120 / PL-GPC 220 Integrated GPC/SEC Systems (CAT#: AM-LE-0127-Y)

Highlights

• Advanced temperature control and detector technology ensure the consistency and accuracy of GPC results The PL-GPC 120 comes standard with a manual sampler, but it can also be operated with an external autosampler
• Our GPC system integrates the pumps of leading HPLC manufacturers, which can achieve 007% invincible flow reproducibility not only in THF close to the ambient temperature, but also in TCB with a temperature higher than 140°C
• The improved refractive index detector includes a new photodiode and uses fiber optic technology to maximize sensitivity while minimizing baseline drift and noise, all of which are critical to good GPC

Cat Number: AM-LE-0127-Y

Application: PL-GPC 120 and PL-GPC 220 can significantly improve resolution and detector performance in many applications.

Model: PL-GPC 120 / PL-GPC 220

Add to Cart



Description

PL-GPC 120 / PL-GPC 220 Integrated GPC/SEC Systems is manufactured by Agilent Technologies, our advanced GPC instruments can ensure that the entire operating temperature range of 30 to 220 °C, regardless of the application, can provide excellent chromatography performance. The PL-GPC 120 system is suitable for temperatures below 120°C, and the PL-GPC 220 is suitable for temperatures below 220°C. The GPC system provides higher accuracy, reproducibility and reliability, and enables automated high sample processing the amount.

Specification

Detector(s):Refractive Index (Opt: LALLS, MALLS, Viscosity, FTIR, ELSD)
Flow Rate:0.1 to 5.0 ml/min
Column Temp. Range: 30 to 220C (depending on model)

Features

• Advanced temperature control and detector technology ensure the consistency and accuracy of GPC results The PL-GPC 120 comes standard with a manual sampler, but it can also be operated with an external autosampler
• Our GPC system integrates the pumps of leading HPLC manufacturers, which can achieve 007% invincible flow reproducibility not only in THF close to the ambient temperature, but also in TCB with a temperature higher than 140°C
• The improved refractive index detector includes a new photodiode and uses fiber optic technology to maximize sensitivity while minimizing baseline drift and noise, all of which are critical to good GPC
• RI ensures excellent signal/noise ratio, even at 220°C