The manufacturer of the QTOF II LC/MS/MS System, Micromass is Micromass. Refurbished Micromass Q-TOF II LC/MS/MS Hybrid Quadrupole/Orthogonal TOF MS complete with three built-in turbo pumps, Edwards vacuum pump, ESI source, lockspray source, PC with MassLynx 4.0 and standard water chiller. Optional: APCI probe. Transmission up to m/z 20,000 for MS analysis, parent ion selection up to m/z 4,000 MS/MS analysis. Hexapole Collision Cell with up to +/- 205 eV Collision Energy. Orthogonal Acceleration TOFMS-2 Analyzer with Mass resolving power of 10,000 (FWHM) 5ppm RMS mass accuracy from m/z 150-900. The Micromass Q-ToF 2 mass spectrometer is an LC-MSMS system, incorporating the simplicity of a quadrupole (MS-1) with the ultra-high efficiency of an orthogonal time-of-flight analyzer (MS-2). The Q-Tof 2 instrument utilizes the orthgonal time-of-flight analyzer to achieve simultaneous detection of ions across the full mass range. This is in contrast to conventional instruments (e.g tandem quadrupoles) that must scan over one mass at a time. The Q-Tof 2 instrument offers up to 100 times more sensitivity than tandem quadrupole instruments when acquiring full product ion (MS/MS) mass spectra. The Q-Tof 2 has a mass-to-charge ratio (upper) limit in excess of m/z 20,000, in both MS and MS/MS modes, enabling the analysis of very large molecules as multiply charged ions. The high resolving power (10,000 FWHM) enables improved mass measurement accuracy for charge state identification of multiply charged ions and greater differentiation of isobaric species. The inherent stability of the reflectron TOF analyzer routinely delivers excellent mass measurement accuracy (~5ppm at 1000 Da). The Q-Tof 2 provides the ultimate in performance for high sensitivity de novo sequencing of sub femtomole quantities of peptides. 'PepSeq' Micromass multi-layered peptide sequencing tool is designed to take full advantage of the high resolution MS/MS data from the Q-Tof 2 (QTOF 2). Initially full product ion (MS/MS) spectra are automatically pre-processed with Micromass charge state de-encryption algorithm (MaxEnt-3). Sequence tags are then established to provide the "cornerstone" from which the complete amino acid sequence is extended to cover the C and N termini.
Specification
Condition: Refurbished, Certified Pre-owned Transmission up to m/z 20,000 for MS analysis Parent ion selection up to m/z 4,000 MS/MS analysis Including: three built-in turbo pumps Edwards vacuum pump ESI source lockspray source PC with MassLynx 4.0 Standard water chiller Optional: APCI probe
Features
Refurbished to meet manufacturer's specification In excellent condition Thoroughly cleaned Money back guarantee Certified with warranty
Related Products
Q TOF Ultima Maldi Mass Spectrometer, Micromass Quantum Probes, Thermo Fisher Scientific Quantum Ultra Parts, Thermo Fisher Scientific