Siemens Advia 2400 Chemistry Analyzer, Operating Temperature Range 18° – 30°C/64° – 86°F, Siemens (CAT#: STEM-AIAEPO-0093-LGZ)

Cat Number: STEM-AIAEPO-0093-LGZ

Application: For chemical analysis.

Model: Advia 2400

Add to Cart



Description

The ADVIA® 2400 clinical chemistry system manages the most demanding workloads and meets high turnaround time (TAT) goals. Its menu includes testing methods for drugs of abuse, therapeutic drugs (TDM) and new assays such as cystatin C and cardiphase® hsCRP. The ADVIA 2400 Clinical Chemistry System provides:

High throughput of up to 2,400 tests/hour (1,800 photometric tests and 600 ISE tests) to manage heavy workloads.
Fast, consistent 2 second cycle time for faster pipeline speed and test throughput.
User-defined automatic repeat, dilution and reflex tests.
Large on-board reagent capacity and optional concentrate reagents help minimize the need for intervention.
Onboard refrigerated storage of controls and reagents for extended stability and increased productivity.
Automated design - no additional hardware required.

Specification

Condition: certified pre-owned
Overview

Type of System: Random, continuous access, batch, discrete processing
Throughput Rate: Up to 2400 tests/hour: 1800 tests/hour colorimetric, 600 tests/hour ISE
Assays Capacity Onboard: 49 including 3 ISE

Sample Handling

Sample Tubes: 5 mL, 7 mL, 10 mL, 2 mL sample cups
Sample Tray: 84 samples, positive sample identification
Bar Codes: Interleaved 2 of 5, code 39, code 128, Codabar (NW7)
STAT Sample Loading: 84, not dedicated
Auto-repeat: Automatic repeat testing from the retained pre-diluted sample
Auto-dilution: Automatic dilution from retained pre-diluted sample
Auto-reflex Testing: Automatic ability to perform 3 additional tests based on results of first test
Primary Probe: Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection
Sample Integrity Check: Qualitative check for hemolysis, lipemia and icterus

Microvolume Technology

Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 test results), retained for auto-repeat until results are available
Predilution Tray: 120 dilution cuvettes
Original Sample Volume: 2 to 30 µL; system uses an average of 2-3 µL per test
Average Reagent Volume: 80-120 µL per test
Storage Capacity Onboard: 20,000 tests average; Usage of concentrated reagents increases maximum capacity

Reaction Area

Reaction Tray: 340 reusable plastic cuvettes
Cuvette Optical Path Length: 6 mm
Reaction Bath: Inert fluorocarbon oil circulation system, 37°C
Photometer: 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm)
Light Source: 12V, 50W halogen lamp, cooled by forced water circulation
Assay Methods: Endpoint, rate reaction, 2-point rate, multi-point homogeneous immunoassay
Reaction Times: 3, 4, 5, 10, 15 and 21 minutes
Automatic Correction: Serum blank, cell blank, measurement point change, sample volume change in reassay
Point Forwarding: Automatically extends linerarity over assay range samples

Reagent Handling

Reagent Tray: 2 trays, 50 positions each, refrigerated
Reagent Capacity Onboard: 46 colorimetric methods
Dispensing System: 2 probes with Liquid Level Sensing and Liquid Surface Verification
Reagent Wedges: 20, 40 and 70 ml bar-code-labeled wedges
Onboard Stability: Up to 60 days
Reagent Inventory Management: Tracks tests remaining, lot number, onboard stability and expiration date
Reagent Dilutions: Capability to dilute concentrated reagents onboard

Open System Capability

Channels: 200 channels, includes user-defined applications
3rd Party Applications: Varies by country, can be configured on system

ISE

ISE: Indirect simultaneous measurement of Na+, K+, Cl-
Sample Volume: 22µL for all three tests
Priming: Automatic priming cycle
Electrode Life: 30,000 samples or 3 months
Throughput Rate: 600 tests/hour; 200 tubes/hour

Calibration/QC

Calibration Interval: Up to 60 days, tracked by software
Auto-Calibration/Auto-QC: User-defined time interval or with new reagent wedge
View Calibration/QC Data: Graphical display of calibration curve and QC, Siemens Remote Service QC monitoring
Calibration/Control Tray: 61 refrigerated positions for calibrators, controls and diluents

Data Management

Computer: Windows® XP, flat panel display
System Documentation: Operator manual and assays sheets on-line
Host Interface: RS 232C bidirectional
Data Storage: 70,000 patient samples
Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via software
Host Query: ASCII; system requests work order or batch of work orders from host

General Specifications

Power Requirements: 100/115/200/220/230/240 V +/– 10%, 30 A, 50/60 Hz, 3 KVA
Water Requirements: Deionized water
Maximum Water Consumption: 40 liters per hour
Drain requirements: Minimum of 10.6 gallons (40) liters per hour.
Dimensions: ADVIA 2400: 52.8 (h) x 67.4 (w) x 34.1 (d) in, 134 (h) x 171.1 (w) x 86.7 (d) cm
Weight: ADVIA 2400: 1,389 lbs. (630 kg)
Compliance: cUL, CSA, CE
Noise Specifications: Open cover less than 70 db, closed cover less than 45 db
Average Heat Output: 5,374 BTU/hour
Operating Temperature Range: 18° – 30°C/64° – 86°F
Ambient Humidity: 40% – 70%

Related Products

Beckman Coulter AU680 Chemistry Analyzer, Total Reaction Volume 120–425 μL, Beckman Coulter (CAT#-STEM-AIAEPO-0037-LGZ)
Beckman Coulter AU680 wISE Chemistry Analyzer, Reaction Temperature 37°C, Beckman Coulter (CAT#-STEM-AIAEPO-0038-LGZ)
Beckman Coulter UniCel DxC 600 Chemistry Analyzer, 110V-220V, Beckman Coulter (CAT#-STEM-AIAEPO-0039-LGZ)
Beckman Coulter UniCel DxC 600 Pro Chemistry Analyzer, Sample Size Max 40 μL, Beckman Coulter (CAT#-STEM-AIAEPO-0040-LGZ)
Beckman Coulter UniCel DxC 800 Chemistry Analyzer, Beckman Coulter (CAT#-STEM-AIAEPO-0041-LGZ)
Beckman Coulter UniCel DxC 800 Pro Chemistry Analyzer, Weight 782 kg, Beckman Coulter (CAT#-STEM-AIAEPO-0042-LGZ)
Advertisement