Special Sterilizer For Medicine Package Material, BXM-110VE-P, Shanghai Boxun Medical Biological Instrument Corp.
1. The organic combination of metal materials and plastic parts can effectively isolate the high surface temperature in working state while ensuring the durability of the body, so as to ensure the safety of operation;
2. Classic hand wheel quick door opening structure, with mechanical self-locking and gated sensing control double protection, to ensure that the cover can not start running properly, can not open the cover until the safety pressure;
3. PMMA I operating system, capacitive touch screen, touch display integrated, controlled by microcomputer intelligent program, provides the operating parameters and working status diagram of the equipment at the working stage, with multi-level password management;
4. Water resistance test procedure of glass particles: Put the conical bottle into the pressure steam sterilizer, open the exhaust valve and heat it at a constant speed. Steam escapes from the exhaust port in large quantities after 20-30 minutes and continues to escape for 10 minutes. Close the exhaust valve and continue to heat, increasing the temperature to 121℃ in 20-22 minutes at an average rate of 1℃/min. Time begins when the temperature is reached. After being kept at 121℃±1℃ for 30 minutes, the temperature is slowly cooled and reduced to 100℃ in 40-44 minutes at an average of 0.5℃/min (to prevent vacuum formation). When the temperature is below 95℃, remove from pressure steam sterilizer and cool to room temperature. (The product conforms to the test requirements of the Chinese Pharmacopoeia for drug packaging materials in 2020)
5. Water resistance test procedure of inner surface: Put the tested product into the pressure steam sterilizer, open the exhaust valve, and heat it at a uniform speed. Steam escapes from the exhaust port in large quantities after 20-30 minutes, and continues to escape for 10 minutes. Close the exhaust valve, continue heating, and raise the temperature to 121℃ in 20-22 minutes at an average rate of 1℃/min. Start timing when the temperature is reached. After 60 minutes at 121 ° C ±1 ° C, the temperature is cooled and decompressed slowly to 100 ° C in 40-44 minutes at an average rate of 0.5 ° C /min (to prevent vacuum formation). When the temperature is below 95℃, the sample is removed from the pressure sterilizer and cooled to room temperature. (The product conforms to the test requirements of the Chinese Pharmacopoeia for drug packaging materials in 2020)
6. Test procedure for firmness of aluminum cover coating: Take proper amount of the product and keep it at 121℃±2℃ for 30 minutes, including steam sterilization at 130℃±2℃ for 5 minutes. (The product conforms to the test requirements of the Chinese Pharmacopoeia for drug packaging materials in 2020)
7. Custom sterilization: 6 levels of different cold air discharge procedures can be selected according to the difference in penetration of the sterilizer steam to ensure the thorough discharge of cold air;
After sterilization, 6 levels of different pressure relief rates can be preset to ensure that the fungicide of different species can be cooled quickly to the temperature at which the lid can be opened without causing sample loss;
8. With electric drainage function, one-button drainage, more convenient operation;
9. Standard fan rapid cooling system, shorten the waiting time for opening the cover;
10. Three levels of authority management including engineer, administrator and operator;
11. With 100-hour countdown reservation function;
12. Standard g1/2A test pipe thread hole
13. Safety guarantee: with fault detection function, overtemperature protection, water off protection, mechanical self-locking, closed cover inspection system, overpressure self-relief protection, anti-hot protection, independent electronic overpressure protection and other multiple safety guarantee