Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Tecan MiniPrep 75 Liquid Handler, Tecan (CAT#: STEM-LAHT-0008-LGZ)

Highlights

1. Liquid handling performance varies depending on: fluid type, nozzle type, tubing configuration, and environmental conditions.
2. MiniPrep can be used in a wide range of applications: Nucleic Acid Extraction and Purification ( Solid Phase Extraction (SPE), or Magnetic Bead Separation (MBS) ), Mother-Daughter Plate Replication, ELISA Assays, Immunophenotyping, LC Injection, Cell-Based Assays and Separations, Protein Assays.

Cat Number: STEM-LAHT-0008-LGZ

Application: For liquid handling.

Model: MiniPrep 75

Add to Cart



Description

The manufacturer of Tecan MiniPrep 75 Liquid Handler is Tecan. Model is MiniPrep 75. Accuracy and precision were measured by dilute salt solution (0.05 N NaCI).

Specification

Condition: used
Pipetting Arms: 1 or 2
Microplate Capacity Deck: 12
Footprint: (W) 815 mm (32.1") x (D) 600 mm (23.6")x (H) 515 mm (20.3")(H does not include Z-rack)
Probe Travel Range: (W) 643 mm (25.3") x (D) 300 mm (11.8")x (H) 165 mm (6.5")
Weight: ~46 kg (100 pounds)
Input Voltages: Auto-selecting 110/230 VAC +/- 10%
Frequency: 47 - 63 Hz
Maximum Power: 250 Watts
384 Well MTP Support: Yes
Diluter 1, 8 Channel: Yes
Disposable Tip: Yes
LC Injection: Yes
Volume Range: 0.5 µL - 25.0 mL
Syringe Sizes: 250 µL - 25.0 mL
Accuracy: <1% @ full stroke with 1.0 mL syringe*
Precision: <0.05% CV @ full stroke with 1.0 mL syringe*
Minimal Detectable Volume: 50 µL of ionic fluid in a 96 well flat bottom standard microplate format. A minimum 1 mm of ionic liquid level height is necessary for reliable liquid detection.
Standard Software: Gemini Software for MiniPrep

Features

1. Liquid handling performance varies depending on: fluid type, nozzle type, tubing configuration, and environmental conditions.
2. MiniPrep can be used in a wide range of applications: Nucleic Acid Extraction and Purification ( Solid Phase Extraction (SPE), or Magnetic Bead Separation (MBS) ), Mother-Daughter Plate Replication, ELISA Assays, Immunophenotyping, LC Injection, Cell-Based Assays and Separations, Protein Assays.

Related Products

Zymark Bio Robot RapidPlate Robotic Liquid Handler, Zymark(CAT#-STEM-LA/HT-0005-LGZ)
Tecan Freedom EVO 100-2 AIR LIHA Liquid Handler, Tecan(CAT#-STEM-LA/HT-0006-LGZ)
Matrix PlateMate 2x2 Liquid Handler, Thermo Fisher Scientific(CAT#-STEM-LA/HT-0009-LGZ)
BioTek Precision 2000 Robotic Liquid Handler, Bio-Tek Instruments(CAT#-STEM-LA/HT-0010-LGZ)
Syro II Peptide Parallel Peptide Synthesis System Liquid Handler, Biotage(CAT#-STEM-LA/HT-0011-LGZ)