Thermo ISQ LT Single Quadrupole GC/MS System, Thermo Fisher Scientific (CAT#: STEM-MSPO-0195-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-MSPO-0195-ZJF

Application: For measuring the mass-to-charge ratio (m/z) of one or more molecules present in a sample

Add to Cart



Description

The manufacturer of the Thermo ISQ LT Single Quadrupole GC/MS System, Thermo Fisher Scientific is Thermo Fisher Scientific.
Refurbished Thermo ISQ LT Single Quadrupole GC/MS complete with Trace 1310 GC and Xcalibur PC workstation.

Specification

Condition: Refurbished, Certified Pre-owned
Mass Range: 1.2 to 1100 U with Unit Mass Resolution
Detectors: DynaMax XR
EI Full Scan Installation Specification: 1 µL of 1 pg/µL Octafluoronaphthalene (OFN) Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U: 600: 1 Using Helium as Carrier Gas
Electron Energy: Adjustable From 0 to 150 eV
Emission Current: Up to 350 µA
Mass Filter: Dual-Stage Mass Filter with Off-Axis Ion Guide and Solid, Homogeneous Non-Coated Quadrupole Rods
Modes: Standard: Electron Ionization (EI), with Full Scan, SIM, and Sequential Full Scan/SIM; Optional:
Chemical Ionization, Including PCI, NCI, PPINICI and EI/CI Combination
Negative Chemical Ionization Installation Spec: 2 µL of 100 fg/µL of OFN Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U Using Methane Reagent Gas: 600: 1 Using Helium as Carrier Gas
Pumping Systems: Standard Capacity (>60 L/s) or High-Capacity (>230 L/s), or Extended Capacity (300 L/s) Turbomolecular Pump with 3.3 m3/h Mechanical Pump; Optional Oil-Free Scroll Pump
Reagent Gas: Software-Switchable Dual Reagent Gas with Digital Flow Control
Scanning Capabilities: Scan Rate: Up to 20,000 U/Sec; Scan Cycles: 97 Scans/Sec to Disc When Scanning Across 125 U
Source Type: ExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization Modes
Vacuum Probe Interlock: Vacuum Probe Interlock to Remove Entire Source or Change Ionization Modes Without Venting
Item Description: ISQ Single Quadrupole Mass Spectrometer

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty