Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Thermo Neslab ThermoFlex 2500 Chiller, Thermo Fisher Scientific (CAT#: STEM-GLEPO-0131-ZJF)

Highlights

Turbine T1 pump – 3.5gpm at 60 psig
2500W (8538 BTU) cooling capacity at 20°C
Voltage requirement: 208-230 VAC/60Hz, SINGLE PHASE

Cat Number: STEM-GLEPO-0131-ZJF

Application: Provide a continuous supply of fluid at a constant temperature and volume.

Add to Cart



Description

The Thermo Neslab ThermoFlex 2500 Chiller is manufactured by Thermo Fisher Scientific.
The Thermo Scientific Neslab ThermoFlex 2500 recirculating chillers are designed to provide a continuous supply of fluid at a constant temperature and volume. This unit is WATER COOLED and also offers a refrigeration system, heat exchanger, recirculating pump, polyethylene reservoir, and a microprocessor controller.
The pre-owned products will be thoroughly cleaned and fully tested to perform at manufacturer specifications before shipping.

Specification

Condition: Certified Pre-Owned
Electrical: 208-230VAC, 50/60Hz, 24 Amps
Refrigerant: R134a, 29 oz.
Design Pressure: 200-348 PSI
Operating Range: 0 to 40°C
Control Accuracy: ±1.0°C
Cooling Capacity at 20°C: 3385W/11,543BTU/Hr.
Flow Rate: 40L/Min.
Max Discharge Pressure: 3.5bar/51psi.
Filling Volume: 245-Liters

Features

Turbine T1 pump – 3.5gpm at 60 psig
2500W (8538 BTU) cooling capacity at 20°C
Voltage requirement: 208-230 VAC/60Hz, SINGLE PHASE
Set Point Temperature Range: +5°C to +40°C
Ambient Temperature Range: +10°C to +40°C
7.2 liter (1.9 gallon) Reservoir Volume
Water Cooled Condenser uses facility water to remove application heat
Pressure relief valve that allows the user to set the maximum fluid pressure to meet application requirements (available as an internal or external component)
Flow Readout allows for monitoring the flow rate via controller readout
Auto Refill allows for automatic refilling from a customer supplied water source to ensure fluid level is maintained
Anti-Drainback prevents fluid from flowing back to the reservoir when the chiller is installed below the application
Partial flow internal DI cartridge minimizing footprint and proving fluid resistivity between 1 & 3 m0hm
SEMI S2 Compliant – S2-0703, S8-0705, S14-0704 & F47-0706

Related Products

Unused Edgestar Household Mini Freezer, Edgestar
Scientemp 45-01A Low Temp Freezer, Scientemp Corporation
Norlake Undercounter Freezer, Nor-Lake, Inc.
Norlake Undercounter Freezer, Nor-Lake, Inc.
Fisher Scientific Laboratory Undercounter Freezer, Thermo Fisher Scientific
Thermo Laboratory Undercounter Freezer, Thermo Fisher Scientific
Advertisement