Thermo Scientifics NanoDrop 2000c Spectrophometer, 190 – 840 nm, Thermo Scientific (CAT#: STEM-SPO-0050-YJL)

Highlights

Thermo Scientific NanoDrop™ Series Spectrophotomers
Uses patented sample retention technology
Readings can be produced in less than 5 seconds.

Cat Number: STEM-SPO-0050-YJL

Application: It is used for the identification and quantifying microscopic samples

Model: NanoDrop 2000C

Add to Cart



Description

Thermo Scientifics NanoDrop 2000c Spectrophometer, 190 – 840 nm, model NanoDrop 2000C, is manufactured by Thermo Scientific. The Thermo Scientific NanoDrop™ 2000 features direct easy measurements- Just pipette and wipe. The NanoDrop™ 2000 is much faster and more accurate at measuring using a conventional spectrophotometer. Direct measurement means that accurate readings can be produced in less than 5 seconds.
Tha NanoDrop™ 2000 uses patented sample retention technology that allows for sample sizes of as little as 0.5 µL. The NanoDrop™ 2000 features full spectral output and is capable of measuring DNA, RNA (A260), Protein (A280), concentration and sample purity (260/280 ration). The NanoDrop™ 200 has a concentration range of 2ng/µl through to 15,000 ng/µL dsDNA without dilutions. Other features of the NanoDrop™ 2000 include:
Pre-configured methods for common applications such as Nucleic Acid, Protein A280, Microarray, Proteins and Labels, Bradford, BCA, Lowry and Pierce 660nm – and more
User-friendly software that includes Custom Methods and data export capabilities
Simple self calibration check using control fluid – no instrument adjustments
Low-cost operation – no plates or other consumables
Other NanoDrop™ Models- NanoDrop™ 2000c, NanoDrop™ 8000 and NanoDrop™ Lite
Thermo Scientific NanoDrop™ 2000c UV-Vis Spectrophotometer with Cuvette Capability
Thermo Scientific NanoDrop™ 2000c– The NanoDrop™ 2000c is a dual-mode UV-Vis Spectrophotometer with Micro-Volume AND
Cuvette Capability for Nucleic Acid and Protein Quantization shares all. The features of the NanoDrop™ 2000c but also features – plus cuvette mode.
Thermo Scientific NanoDrop™ 8000 Multi-Sample Micro-Volume UV-Vis Spectrophotometer
The Thermo Scientific NanoDrop™ 8000 can measure more samples in less time with the same reliability and patented sample retention technology of the NanoDrop™ 2000.
Thermo Scientific NanoDrop™ Lite Basic Microvolume UV-Vis Spectrophotometer
The Thermo Scientific NanoDrop™ Lite is a basic Microvolume UV-Vis Spectrophotometer for simple sample analysis delivered in compact footprint.The NanoDrop™ Lite uses the same sample retention system that has become a hallmark of NanoDrop™ instruments. While it is designed with fewer features than the NanoDrop™ 2000 and NanoDrop™ 8000 series, the NanoDrop™ Lite delivers where it counts: rapid, accurate and reproducible micro volume measurements without the need for dilutions.
NanoDrop™ Pedestal Measurements
The patented sample retention system used by the Thermo Scientific NanoDrop™ 2000 and NanoDrop™ 2000c allows for the analysis of 0.5 µl – 2.0 µl samples, without the need for cuvettes or capillaries.

Specification

Condition: Certified Pre-Owned
Minimum Sample Size: 0.5 µl
Sample Number: 1
Path Length: 1 mm (auto-ranging to 0.05 mm)
Light Source(s): Xenon flash lamp
Detector Type: 2048 – element linear silicon CCD array
Wavelength Range: 190 – 840 nm
Wavelength Accuracy: 1 nm
Spectral Resolution: < 1.8 nm (FWHM at Hg 253.7 nm)
Absorbance Precision: 0.002 (1 mm path)
Absorbance Accuracy: 3% (at 0.74 at 350 nm)
Absorbance Range: 0.04 – 300 (10 mm equivalent)
Detection Limit: 2 ng/µl (dsDNA)
Maximum Concentration: 15,000 ng/µl (dsDNA)
Measurement Time: < 5 seconds
Footprint: 14 x 20 cm
Weight: 2.0 kg
Sample Pedestal Material of Construction: 303 stainless steel and quartz fiber
Operating Voltage: 12 vdc
Operating Power Consumption: 12 – 18 W (max 30 W)
Standby Power Consumption: 5 W
Software Compatibility: Professional versions of Windows 7 (32 bit and 64 bit), Windows Vista (32 bit), Windows XP (32 bit)
Cuvette specifications for NanoDrop™ 2000c Model Only
Z-Height: 8.5 mm
Heating: 37 +/- 0.5 ℃
Stirrer: 150-850 rpm
Path Length: 10, 5, 2, 1 mm
Absorbance Range: 0.008 – 1.5
Detection Limit: 0.4 ng/µl (dsDNA)
Maximum Concentration: 750 ng/µl (dsDNA)
Measurement Time: < 3 seconds
Cuvette Dimensions: 12.5 mm x 12.5 mm, up to 48 mm H
Type: Masked cuvette
UL/CSA and CE: All units are approved to these standards

Features

Thermo Scientific NanoDrop™ Series Spectrophotomers
Uses patented sample retention technology
Readings can be produced in less than 5 seconds.
Sample sizes of as little as 0.5 µL
Pre-configured methods for common applications such as Nucleic Acid, Protein A280, Microarray, Proteins & Labels, Bradford, BCA, Lowry and Pierce 660nm – and more
User-friendly software that includes Custom Methods and data export capabilities
Simple self calibration check using control fluid – no instrument adjustments
Low-cost operation – no plates or other consumables

Related Products

Beckman DU 800 Spectrophotometer, 190 - 1100 nm, Beckman Coulter (CAT#: STEM-SPO-0039-YJL)
Nanodrop 8000 Spectrophotometer, 220 – 750 nm, Thermo Scientific (CAT#: STEM-SPO-0040-YJL)
Thermo NanoDrop One, Thermo Scientific (CAT#: STEM-SPO-0041-YJL)
Thermo NanoDrop One-C, Thermo Scientific (CAT#: STEM-SPO-0042-YJL)
Thermo Scientific NanoDrop 1000, 220 - 750 nm, Thermo Scientific (CAT#: STEM-SPO-0043-YJL)
Agilent 8453 Diode Spectrophotometers, 190 – 1100 nm, Agilent (CAT#: STEM-SPO-0044-YJL)
Advertisement