Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Unchained Labs Grunt Automated Buffer Prep and Exchange System, Unchained Labs (CAT#: STEM-LAHTPO-0003-ZJF)

Highlights

Hands-off protein formulation with the GRUNT
Record every step of the process and cut down on their documentation time
In excellent condition

Cat Number: STEM-LAHTPO-0003-ZJF

Application: For automated biologic formulations preparation.

Model: GRUNT

Add to Cart



Description

The manufacturer of the Unchained Labs Grunt Automated Buffer Prep and Exchange System is Unchained Labs.
The GRUNT unchains researchers from the time-consuming, old-school processes for making biologic formulations. Common steps like buffer prep, exchange, dialysis and sample concentration for a formulation screen can take days and it's all manual. With the GRUNT, scientists only spend 20 minutes on set up, picking buffers, entering parameters and loading lab wear. The GRUNT handles everything else. It does all the dirty work so they can focus on the big stuff.
The pre-owned products will be thoroughly cleaned and fully tested to perform at manufacturer specifications before shipping.

Specification

Condition: Certified Pre-Owned
Electrical: 100-240VAC, 50/60Hz, 12 Amps, 1320W

Application
Buffer exchange volume range: Unfilter 24: 0.45-8 mL Unfilter 96: 100-450 μL
Formulations: Unfilter 24: Up to 24 formulations in parallel Unfilter 96: Up to 96 formulations in parallel
Sample types: Antibodies and other proteins, nucleic acids, lipid nanoparticles (LNPs), adeno-associated viruses (AAVs), virus-like particles (VLPs)
Exchange time at full volume (96%, at 10 mg/mL IgG): Unfilter 24: 4.5 hours* Unfilter 96: 3 hours*
Protein concentration (range): Up to 200 mg/mL*
Target concentration accuracy: ± 10%*
Sample recovery: ≥96%*
*Sample and formulation dependent.

System
Volume measurement: Ultrasonic sensor
Exchange pressures: 15, 30 or 60 psi
Operating temperature: Room temperature
Buffer exchange orbital mixing: Unfilter 24: Optimized at 700 rpm Unfilter 96: Optimized at 875 rpm Duty cycle programmable
Physical: 96 cm L x 81.2 cm D x 130 cm H, 220 kg (instrument) 160 cm L x 100 cm D x 198 cm H, 270 kg (instrument and table)
Electrical: Voltage 100-260 VAC, 50-60 Hz
Nitrogen or CDA requirement: Pressure 0.55–0.9 MPa (80–130 psi) Flow rate 40 L/s (85 cfm) minimum

Features

Hands-off protein formulation with the GRUNT
Record every step of the process and cut down on their documentation time
In excellent condition
Thoroughly cleaned
Fully tested to perform at manufacturer specifications

Related Products

Siemens VersaCell Laboratory Sample Dispenser, Siemens Healthcare GmbH
CambTEK RES Rapid Extraction System, CambTEK Ltd

Other recommended products

Advertisement