1260 Infinity II G7121A Fluorescence Detector, Agilent Technologies (CAT#: STEM-CPO-0338-ZJF)

Highlights

Lowest limits of detection with a Raman S/N > 3000 (using dark signal noise reference). Simplified optical design for optimized baseline stability.
Up to 100 % resolution gain in fast LC using a 74 Hz data acquisition rate.
Long-life xenon lamp for highest sensitivity. The long-life (> 4000 hours) flash lamp, lamp reference system and efficient light collection ensure constant lamp energy for maximum excitation of fluorophores.

Cat Number: STEM-CPO-0338-ZJF

Application: For chromatography

Model: 1260 Infinity II G7121A

Add to Cart



Description

The manufacturer of the 1260 Infinity II G7121A Fluorescence Detector, Agilent Technologies is Agilent Technologies.
Refurbished Agilent 1260 Infinity II G7121A Fluorescence Detector. (Agilent FLD)
The proven optical and electronic design of the Agilent 1260 Infinity II Fluorescence Detector provides highest sensitivity for the analysis of trace-level components. Time-programmable excitation and emission wavelength switching allows you to optimize the detection sensitivity and selectivity for your specific applications. High-speed detection with up to 74 Hz data rates keeping you pace with the analysis speed of fast LC.

Specification

Condition: Refurbished, Certified Pre-owned
Weight: 11.9 kg (26.2 lbs)
Dimensions (height × width × depth): 140 x 396 x 436 mm (5.5 x 15.6 x 17.0 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 70 VA, 60 W
Ambient operating temperature: 4-40 °C (39-104 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15092 ft)
Safety standards: IEC, EN, CSA, UL: Installation category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B

Features

Lowest limits of detection with a Raman S/N > 3000 (using dark signal noise reference). Simplified optical design for optimized baseline stability.
Up to 100 % resolution gain in fast LC using a 74 Hz data acquisition rate.
Long-life xenon lamp for highest sensitivity. The long-life (> 4000 hours) flash lamp, lamp reference system and efficient light collection ensure constant lamp energy for maximum excitation of fluorophores.
Easy front access enables fast inspection or exchange of the flow cell.
Automatic recognition of all flow cell cartridges provides documentation of instrument parameters and helps to comply with GLP.
Extensive diagnostics, error detection and display with Instant Pilot controller and Agilent Lab Advisor software.