Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

486 Tunable Absorbance Detector, Waters Corporation (CAT#: STEM-CPO-0973-ZJF)

Highlights

Easy to use operator interface
Self-calibration to ensure wavelength accuracy
Battery backup to retain parameter settings when the detector is powered down or during power interruptions

Cat Number: STEM-CPO-0973-ZJF

Application: For High Performance Liquid Chromatography (HPLC)

Model: Waters 486

Add to Cart



Description

The manufacturer of the 486 Tunable Absorbance Detector is Waters Corporation.
The Waters 486 tunable absorbance detector is a single-Channel tunable ultraviolet/visible (UV/VIS) detector designed for high performance liquid chromatography (HPLC) applications. The waters 486 can operate as a stand-alone unit (with a chart recorder) or with other Waters system modules, such as the Waters 860 Networking Computer System, or the Water 745/745B or 746 integrators. The 486 provides a usable light intensity over the wavelength range of 190-600 nanometers (nm), Although its primary use is in the ultraviolet wavelength range between 190 and 380 nanometers. The maximum sensitivity of the instrument is 0.001 absorbance units full scale (AUFS).

Specification

Condition: Pre-owned
Wavelength range (single, fixed wavelength): 190 to 600 nm
Wavelength accuracy: ± 2 nm
Wavelength repeatability: ± 0.25 nm
Noise: ± 1.0 x 10-5 AU, 1 second filter setting, 210 to 280 nm) dry cell
Drift:
1.0 x 10-4 AU per °C (after warm-up)
1.0 x 10-4 AU per hour (after warm-up)
Sensitivity Setting Range: 0.001 to 2.0 AUFS (under software control)
Filter Setting Range: 0.1 to 5.0 seconds (under software control)
Bandwidth: 8 nm
Lamp Source: Deuterium arc lamp
Flow cell: Dual beam Taper-Cell design
Path length: 10 mm (standard, analytical)
Cell volume: 8 ul (standard, analytical)
Pressure limit: 1000 psi
Materials: 316 stainless steel, Dynasil Suprasil II, Teflon

Features

Easy to use operator interface
Self-calibration to ensure wavelength accuracy
Battery backup to retain parameter settings when the detector is powered down or during power interruptions
A deuterium arc lamp
The patented Taper-Cell flow design switch reduces refractive index interference with the absorbance signal
Optional cells: Non-metallic, Semi-prep, Microbore, High pressure (A cell optimized for operation in LC/MS)
Lamp shut-off to lengthen usable lamp life
User selectable chart mark on IV integrator output (standard on 10mV)
Wavelength scanning for determination of optimal wavelength
Diagnostic routines to verify proper functioning
A modular design for easy servicing