Abbott Architect i4000SR Immunoassay Analyzer, Sample Capacity 285, Abbott (CAT#: STEM-AIAEPO-0175-LGZ)

Cat Number: STEM-AIAEPO-0175-LGZ

Application: For in vitro diagnostic use only.

Model: Architect i4000SR

Add to Cart



Description

The ARCHITECT i4000SR is a multi-module system consisting of two ARCHITECT i2000SR systems, with all the proven benefits of the ARCHITECT series of instruments. The ARCHITECT i4000SR provides increased productivity for laboratories with high immunoassay needs. Large loading capacity allows ARCHITECT i4000SR to provide high throughput of high quality STAT results when needed.

The ARCHITECT i4000SR Immunoassay Analyzer offers a maximum throughput of up to 400 tests per hour. The ARCHITECT i4000SR has a loading capacity of 285 samples, 35 priority zones and 250 routine zones, with 50 frozen reagent positions.

Specification

Condition: certified pre-owned
Methods: CHEMIFLEX
Maximum Throughput: Up to 400 tests/hour
Sample Types: Serum, Plasma, Whole Blood, Urine
Sample Tubes: Height: 72-102 mm; Diameter: 9.6-16.1 mm
Sample Cup: Yes (50 µl dead volume)
Sample Capacity: 285
Sample Barcode Types: Code 39, Codabar, Interleaved 2 of 5, Code 128
Sample Result Storage: 50,000
Sample Volume: 10-150 μL, Average: 57 μL
Automatic Dilution: Yes
Sample Probe Carryover: ≤0.1 parts per million
Reagent Capacity: 50 refrigerated positions
Reagent Type: 100% liquid ready-to-use
Reagent Onboard Stability: 14-30 days
Calibration Frequency: Calibrate with new lot number, if controls are out of range or if specified otherwise within the package insert
Sample, Clot and Bubble Detection: Yes
Reagent Pressure Monitoring: Yes
Sample Interference Measurement: No
System Control Center: 1 SCC, with color touchscreen monitor, keyboard and mouse
On-board Maintenance Records: Yes
Online Error Code Help: Yes
Host Interface: Bidirectional, serial RS-232 interface, host query option available
Remote Diagnostics: AbbottLink
Dimensions (H x W x D): 48” x 127” x 49”; 121.9 x 322.6 x 124.5 cm
Weight: 2,162 lbs; 980.7 kg
Electrical Requirements: AC 180-264V, 47-63 Hz
Water Requirements: Purified water to dilute buffer concentrate
Heat Output*: 4280 BTU/hr, running mode
Sample Loading: RSH

Related Products

Ortho Clinical Vitros 3600 Immunodiagnostic System, Weight (Metric) 1062 kg, Ortho Clinical (CAT#-STEM-AIAEPO-0186-LGZ)
Roche Cobas 6000 Core Immunology Analyzer, Sample Size Max 35 μL, Roche (CAT#-STEM-AIAEPO-0187-LGZ)
Roche Cobas E411 Disk Immunology Analyzer, Sample Size Max 50 μL, Roche (CAT#-STEM-AIAEPO-0188-LGZ)
Roche Cobas E411 Rack Immunology Analyzer, Patient Sample Capacity 75, Roche (CAT#-STEM-AIAEPO-0189-LGZ)
Roche Cobas E601 Immunology Analyzer, Sample Size Max 50 μL, Roche (CAT#-STEM-AIAEPO-0190-LGZ)
Roche Cobas E602 Immunology Analyzer, Patient Sample Capacity 300, Roche (CAT#-STEM-AIAEPO-0191-LGZ)
Advertisement