Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

ALC-ANE6-VD(Y) Animal Anesthesia ventilator, SHANGHAI ALCOTT BIOTECH CO., LTD. (CAT#: STEM-LEAR-0059-YJL)

Highlights

Accurate control, stable performance, easy operation and durability.
The anesthetic gas is inhaled into the body by controlling the animal's breathing through an electronically controlled ventilator, which is suitable for various short-term and long-term controlled respiratory anesthesia.
The anesthesia ventilator is safe, reliable, and has good airtightness to prevent accidental evaporation of the anesthetic.

Cat Number: STEM-LEAR-0059-YJL

Application: Used to control animal breathing and inhalation into the body, suitable for various short-term and long-term controlled respiratory anesthesia

Model: ALC-ANE6-VD(Y)

Add to Cart



Description

ALC-ANE6-VD(Y) Animal Anesthesia ventilator, model ALC-ANE6-VD(Y) is manufactured by SHANGHAI ALCOTT BIOTECH CO., LTD.
Inhalation anesthesia is when an animal inhales anesthetic drugs into the lungs through an anesthesia machine, absorbs them through the pulmonary capillaries, enters the blood circulation, and reaches the central nervous system to produce an anesthetic effect. It can quickly put animals into a safe and effective state of unconsciousness and relax muscles. Compared with intravenous anesthesia, the depth of anesthesia is easier to adjust and animals wake up faster. It is a commonly used method of animal anesthesia. The ALC-ANE6-VD(Y) animal anesthesia ventilator is equipped with high-quality imported anesthesia vaporizer and animal ventilator.

Specification

Inhalation-to-exhalation ratio adjustment range: 1: 5~5: 1

Features

Accurate control, stable performance, easy operation and durability.
The anesthetic gas is inhaled into the body by controlling the animal's breathing through an electronically controlled ventilator, which is suitable for various short-term and long-term controlled respiratory anesthesia.
The anesthesia ventilator is safe, reliable, and has good airtightness to prevent accidental evaporation of the anesthetic.
The anesthetic gas output flow rate is accurate and the concentration is stable, not affected by changes in temperature, flow rate, and pressure, and is easy to adjust.
Silent design to reduce experimental noise.
Automatic pressure relief protection when the suction air pressure exceeds the limit value.
The air pressure protection limit can be set.
The tidal volume has a wide applicable range and the breathing frequency adjustment range is wide.
The inhalation-to-exhalation ratio adjustment range is 1: 5~5: 1, in steps of 0.1, and can be set arbitrarily, with up to thousands of inhalation-to-exhalation ratios.
Equipped with an active anesthesia waste gas recovery system to absorb the anesthesia waste gas exhaled by animals to protect staff and the environment.
Built-in air source, no high-pressure gas required, easy to use.
The widely used isoflurane is used as an anesthetic.
Special configurations are provided for various animals, suitable for low-flow anesthesia of animals, ensuring rapid recovery after anesthesia.
Equipped with anesthesia induction box, animal anesthesia mask, tracheal intubation and other equipment.
Floor-standing stand design, solid structure, flexible movement and convenient use.

Related Products

Pet Hydration Chamber, BEIJING FINETER VESSEL CO.,LTD (CAT#: STEM-LEAR-0332-YJL)
High Temperature Hydrolysis Treatment Equipment for Laboratory Animal Carcasses, BEIJING FINETER VESSEL CO.,LTD (CAT#: STEM-LEAR-0333-YJL)
Smoke Generator, Data Sciences Internatinal, Inc. (CAT#: STEM-LEAR-0770-YJL)
Single Animal Exposure System, Data Sciences Internatinal, Inc. (CAT#: STEM-LEAR-0772-YJL)
Laboratory Animal Group Exposure System, Data Sciences Internatinal, Inc. (CAT#: STEM-LEAR-0773-YJL)
iPRECIO Micro Infusion Pumps, 0.1ul/hour, Data Sciences Internatinal, Inc. (CAT#: STEM-LEAR-0776-YJL)