Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Echo 550® LIQUID HANDLER, Labcyte (CAT#: AM-AUTO-0173-LY)

Highlights

Most diverse range of applications in the Echo Liquid Handler family
Impacts all phases of drug discovery process
Saves money and increases data quality in large genomics projects

Cat Number: AM-AUTO-0173-LY

Application: for GENOMICS: SANGER SEQUENCING ASSAY SET-UP<br />for DRUG DISCOVERY: HIGH-THROUGHPUT SCREENING, HIGH CONTENT SCREENING, ASSAY-READY PLATES, EPIGENETICS, IC50

Model: Echo 550® LIQUID HANDLER

Add to Cart



Description

The Echo 550® LIQUID HANDLER is manufactured by Labcyte. The precise nL transfer volumes, the any-well-to-any-well transfer capability, and flexible applications software of the Echo 550 Liquid Handler enables researchers to set up experiments not possible with traditional liquid handling.

Specification

Drop volume: 2.5 nL
Volume transfer range: 2.5 nL – 10 µL (dependent on fluid type, assay, and source plate used)
Reagents supported: DMSO, PCR and qPCR reagents, synthetic biology reagents, NGS reagents, primers and probes, cell culture media, proteins, nucleic acids, up to 50% glycerol, serum, plasma, antibodies, enzymes, and protein crystallography reagents
Transfer accuracy: <10% deviation from target volume
Transfer precision: <8% CV (except protein crystallography fluid class)
Source labware compatibility: All Echo Qualified 384- and 1536-well Microplates
Destination labware compatibility: All Echo Qualified Microplates and most ANSI-compliant/SBS-standard microplates in 96-, 384-, 1536-, and 3456-well formats 8 to 16 mm well height
Barcode reader options: Short-side and/or long-side
Dimensions: 53.9 cm width x 68.3 cm depth x 92.5 cm height (21.2 x 26.9 x 36.4 inches)
Weight: 128 kg (283 lbs)
Working envelope: Additional 25.4 cm (10 inches) on top, 2.5 cm (1 inch) on sides, 7.6 cm (3 inches) at front, 30.5 cm (12 inches) at back
Electrical: AC 120V, 50/60 Hz, 10 A or AC 230V, 50/60Hz, 5 A
Operating temperature: 21°C ± 5°C (70°F ± 9°F)
Vacuum: House supply minimum 200 Torr (266 mbar, 22 inches Hg Vac) OR Standalone vacuum with surge tank, minimum pump speed 2.0 m3/hr, minimum pressure 100 Torr (133 mbar, 26 inches Hg Vac)
Fluid class calibration: No calibration needed

Features

Most diverse range of applications in the Echo Liquid Handler family
Impacts all phases of drug discovery process
Saves money and increases data quality in large genomics projects
Advertisement