Highlights

1. BD C6 flow cytometer 96-well plate and 24-tube rack autosampler.
2. Blue-red laser.
3. Dual light scattering detectors.

Cat Number: STEM-CA-1142-LGZ

Application: For cell assay research.

Model: Accuri C6

Add to Cart



Description

The manufacturer of BD Biosciences Accuri C6 w/ Csampler Flow Cytometer is BD Biosciences. Model is Accuri C6. The BD Accuri C6 flow cytometer is designed to be compact from the ground up and easy to use, suitable for any laboratory and readily accessible by all researchers - experts and novices alike.

Specification

Condition: used
Laser Excitation: 488 nm (rated at 20,000 hr life)
640 nm (rated at 20,000 hr life)
Laser Profile: 10 x 75 µm
Laser Power: 14.7 mW 640 nm Diode Red Laser
20 mW 488 nm Solid State Blue Laser
Scatter Detection: Forward (0 degrees, +/-13)
Side (90 degrees, +/-13)
Emission Detection: 4 colors, standard optical filters
• FL1 533/30 nm (e.g. FITC/GFP)
• FL2 585/40 nm (e.g. PE/PI)
• FL3 > 670 nm (e.g. PerCP, PerCP-Cy™5.5, PE-Cy7)
• FL4 675/25 nm (e.g. APC)
Optical Alignment: Fixed alignment
Flow Cell: 200 µm ID quartz capillary
Minimum Detectable Particle Size: 0.5 µm
Minimum Sample Volume: 300 µL (in 12 x 75 mm tube)
Pre-Set Flow Rates and Core Sizes:
Slow: 14 µL/min, 10 µm core
Medium: 35 µL/min, 16 µm core
Fast: 66 µL/min, 22 µm core
Custom Sample Flow Rates: 10 – 100 µL/min
Custom Core Diameter: 5 – 40 µm
Recommended Sheath Fluid: 0.22 µm filtered, deionized (DI) water
Maximum Events Per Sample: 1 million events per well
Florescence Sensitivity, MESF*: FITC < 150; PE < 100
Scatter Resolution:Resolves human peripheral blood lymphocytes,
monocytes, and granulocytes
Fluorescence Linearity: 2 ± 0.05% for chick erythrocyte nuclei (CEN)
Fluorescence Precision: ≤ 3% CV for CEN
Data Acquisition Rate: 10,000 events/second, maximum
Power Requirements: 100 - 240 VAC, 50/60 Hz
Typical Power Consumption: 154 VA
Heat Output:240 Btu/hour maximum output
Operating Ranges: 15 - 30 °C; < 80% relative humidity
Instrument Size: 11”H x 14.75”W x 16.5”D (27.9 x 37.5 x 41.9 cm)
Foot Print with Fluid Bottles: 11”H x 21.5”W x 16.5”D (27.9 x 54.6 x 41.9 cm)
Weight: 30 lbs (13.6 kg)
Fluid bottle capacity: 2 L sheath fluid, 2 L waste,
250 mL cleaner, 250 mL decontamination
Signal Processing: 24-bit datapath
Computer Interface: USB 2.0

Features

1. BD C6 flow cytometer 96-well plate and 24-tube rack autosampler.
2. Blue-red laser.
3. Dual light scattering detectors.
4. Optical filters such as FITC, PE, PerCP and APC.
5. The compact optical design, fixed alignment and pre-optimized detector settings make the system easier to use.
6. Optional filters and optional laser modules expand the available fluorescent color combinations.
7. The system is compact and can carry weight (13.6 Kg).
8. The software interface is intuitive.

Related Products

Life Technologies Attune NXT AFC2 w/ Attune NxT Autosampler. Blue And Red Lasers. Flow Cytometer, Thermo Fisher Scientific(CAT#-STEM-CA-0399-LGZ)
BD Biosciences FacsAria IIu Cell Sorter, BD Biosciences(CAT#-STEM-CA-0542-LGZ)
Luminex Guava Muse Cell Analyzer, Luminex(CAT#-STEM-CA-0546-LGZ)
Millipore Muse Cell Analyzer, Millipore(CAT#-STEM-CA-0549-LGZ)
NanoString Technologies nCounter Sprint Profiler Cell Analyzer, NanoString(CAT#-STEM-CA-0550-LGZ)
Becton Dickinson FACSMicroCount Microbe Counter, Becton Dickinson(CAT#-STEM-GA-0561-LGZ)
Advertisement