Beckman Coulter AU5432 Chemistry Analyzer, 110V-220V, Beckman Coulter (CAT#: STEM-AIAEPO-0033-LGZ)

Cat Number: STEM-AIAEPO-0033-LGZ

Application: For electrolytes, enzymes, blood glucose, metabolites, thyroid, hormones, lipids, therapeutic drug monitoring and drug of abuse monitoring.

Model: AU5432

Add to Cart



Description

The Beckman Coulter AU5432 chemistry system has over 100 tests with a maximum throughput of 6,600 tests per hour. The AU series systems are critically acclaimed open-reagent, high-quality chemical systems that are considered to be among the most popular on the market, especially in the US laboratory market. Chemical analyzers create anomalous patterns by measuring substances in body fluids. The wide range of tests can be grouped into the following categories: electrolytes, enzymes, blood glucose, metabolites, thyroid, hormones, lipids, therapeutic drug monitoring, and drug of abuse monitoring. This analysis can be performed on blood (whole blood, serum or plasma), urine, semen or cerebrospinal fluid. Chemical analysis begins by placing patient samples in individual capsules, test tubes, slides, or sample cups that are transported by conveyor belts in sample racks or carousels in reagent trays. Samples are sampled and then automatically mixed with diluents and reagents in reaction tubes. Reagents are removed from the reagent carousel, which is usually refrigerated to preserve the shelf life of the reagents longer. Reaction tubes are stored and processed in reaction carousels. The reaction carousel has mixing stations (to mix samples and reagents) and wash stations (to rinse test tubes). The tubes are made of glass or plastic, depending on the manufacturer, but must be optically clear so that light can pass through without any scratches or blemishes. Chemical analysis is calculated by the absorbance of specific wavelengths of light as it passes through the sample. All chemical analyzers have a photometer (filter photometer or spectrophotometer) that measures the light absorbance of the sample and calculates the result. Filter photometers use glass filters coated with colored material on a rotating filter wheel, while spectrophotometers use prisms or gratings to isolate these wavelengths from the scanner beam. In both cases, a lamp (usually halogen) is the light source. Spectrophotometry is a more commonly used method than filter photometry, which is currently only available in Johnson & Johnson, Roche Cobas and Siemens size systems. Spectraphometry is used in most other systems, including Abbott, Beckman and Roche Hitachi systems. The process of obtaining results from an absorbance test is classified as either endpoint or kinetics. Endpoint methods incubate the reaction mixture for a predetermined time to reach the endpoint or equilibrium of the reaction. Kinetic methods monitor the reaction as the reagent and sample are mixed, and then determine the rate of change in absorbance, which correlates to the analyte concentration. So kinetic energy is a way faster than the end.

Specification

Condition: certified pre-owned
Assay Methodology: End-point, End-point w/Self Blanking, End-point w/Sample Blanking, Kinetic Rate, Fixed Rate, ISE
Auto Dilution: Yes
Auto Sample Handling: Yes
Complexity: Moderate
Configuration: Floor Model
Depth: 114 cm (45 in)
Direct Sample (STAT): Yes
Height: 126 cm (50 in)
Maintenance Free Electrodes: Yes
Manufacturer: Beckman Coulter
Maximum Throughput: 6600 tests/hour
Number of Assays: 101
On-Board Refrigeration: Yes
Optical Source: Tungston-Halogen Lamp
Optical System: Bi-chromatic; Diffraction Grating; Mono-chromatic; Multi-Wavelength Optics; Potentiometric; Spectro-Photometric; Turbidimetric
Other Features: The AU5431 is comprised of 3 analyzers and 2 ISE units.
Patient Sample Capacity: 300
Point Of Care: No
Power Supply: 110V-220V
Reagent Capacity: 144
Reagent Delivery: Automatic Pipetting
Reagent System: Open
Reagent Type: Liquid
Sample Cycle Time: 5 (sec)
Sample Input Closed Tube: No
Sample Input Type: Sample Cups; Sample Tubes
Sample Size Max: 25 μL
Sample Size Min: 1.6 μL
Sample Types: Plasma, Urine, Serum, CSF
Series: AU5400
Standby Mode: Yes
Test Method: Light Absorbancy; Ion-Selective Electrodes
Water Consumption: 180 (L/hour)
Water OnBoard Supply: No
Water Requirement: Yes
Weight: 1880 kg (4136 lb)
Width: 507 cm (200 in)

Related Products

Roche Urine Chemstrip, Weight 1.8 Ibs, Roche (CAT#-STEM-AIAEPO-0090-LGZ)
Siemens Advia 1200 Chemistry Analyzer, Reagent Capacity 90, Siemens (CAT#-STEM-AIAEPO-0091-LGZ)
Siemens Advia 1800 Chemistry Analyzer, Ambient Humidity 40%-70%, Siemens (CAT#-STEM-AIAEPO-0092-LGZ)
Siemens Advia 2400 Chemistry Analyzer, Operating Temperature Range 18° – 30°C/64° – 86°F, Siemens (CAT#-STEM-AIAEPO-0093-LGZ)
Siemens ADVIA Centaur XPT Immunoassay System, Sample Size Max 200 μL, Siemens (CAT#-STEM-AIAEPO-0094-LGZ)
Siemens Dimension EXL 200 Chemistry Analyzer, Patient Sample Capacity 60, Siemens (CAT#-STEM-AIAEPO-0095-LGZ)
Advertisement