Beckman Coulter AU680 wISE Chemistry Analyzer, 120–425 μL In Ramsey, MN, USA, model AU680 wISE, is manufactured by Beckman - Coulter general laboratory equipment. Meet ever-increasing pressures on time and productivity with ease. The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer delivers field-proven reliability and efficiency to laboratories around the world.
Specification
Condition: Used Weight: 1025 lbs (465 kg) Maximum Heat Dissipation into the Room: 1.0 kW (3400 Btu/hr) Noise Level: 57 dBa Installation Category: II Pollution Degree: 2 Set Speed: 1000 rpm to 80 000 rpm in increments of 100 rpm Speed Control: Actual rotor speed will be +/- 50 rpm of the set speed (above 1000) Speed Display: Indicates rotor speed in increments of 10 rpm at speeds below 1000 rpm, and increment of 100 rpm at speeds above 1000 rpm Set Time: Up to 99 hours and 59 minutes; HOLD for runs of unspecified length Time Display: Indicates time remaining in timed runs, time elapsed in HOLD runs, or estimated time remaining in ?2t runs Set Temperature: 0 to 40 deg C in increments of 1 deg C Temperature Control: +/1 1 deg C of set temperature Display: Indicates rotor temperature in increments of 1 deg C Stability: Within 0.3 deg C of set after equilibrium is reached Acceleration: Selection from two profiles: maximum acceleration from 0 rpm to set speed, or slow acceleration from 0 to 500 rpm, followed by maximum acceleration to set speed Deceleration: Selection from three profiles: full dynamic braking to 0 rpm, slow (full brake to 500 rpm followed by reduced braking to a gentle stop), or no brake Operation: Standard, programmed, or delayed start; instrument memory can store up to nine individual programs Revolution Corner: Displays accumulated total number of rotor revolutions in tens of thousands Barrier Ring: 41-mm (1.63-in.) heat-treated steel alloy armor ring surrounded by a 12-mm (0.50-in.) steel vacuum chamber to provide full protection for the operator Door: 17.5-mm (0.69-in.) high-strength structural steel Vacuum: Diffusion pump in series with a mechanical pump reduces chamber pressure to below 5 microns (0.7 Pa)
Related Products
Beckman Coulter AU640 Chemistry Analyzer, 800 tests/hour In Ramsey, MN, USA (CAT#: STEM-AIPO-0218-YJL) Beckman Coulter AU5432 Chemistry Analyzer, 6600 tests/hour In Ramsey, MN, USA (CAT#: STEM-AIPO-0219-YJL) Beckman Coulter AU5431 Chemistry Analyzer, 5700 tests/hour In Ramsey, MN, USA (CAT#: STEM-AIPO-0220-YJL) Beckman Coulter AU5422 Chemistry Analyzer, 5000 tests/hour In Ramsey, MN, USA (CAT#: STEM-AIPO-0221-YJL) Beckman Coulter AU5421 Chemistry Analyzer, 4100 tests/hour In Ramsey, MN, USA (CAT#: STEM-AIPO-0222-YJL) Beckman Coulter AU480 Chemistry Analyzer, 90–350 μl In Ramsey, MN, USA (CAT#: STEM-AIPO-0223-YJL)