Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Bio-Rad MyCycler Thermal Cycler, 4-100 ℃ In College Park, GA, USA (CAT#: STEM-PCREPO-0136-YJL)

Cat Number: STEM-PCREPO-0136-YJL

Application: Used to run polymerase chain reaction (PCR) for sequencing, cloning, genotyping, mutagenesis, and many other applications

Model: MyCycler

Add to Cart



Description

Bio-Rad MyCycler Thermal Cycler, 4-100 ℃ In College Park, GA, USA, model MyCycler, is manufactured by Bio-Rad thermal cyclers.
The Biorad MyCycler Thermal Cycler, 115V, is a sleek 96-well PCR system with a gradient feature used for gene amplification. This compact thermal cycler features intuitive programming of temperatures, times, and protocols with ready-made templates for ease of viewing, editing, and running protocols. Program protocols with as many as 9 cycles with 9 steps each and repeats up to 99 times per cycle. The MyCycler’s self-adjusting heated lid maintains accurate temperature and accommodates standard 0.2 ml thin-wall PCR tubes, strips, and plates. Temperature monitoring and control can be performed either via algorithm, which uses the experimentally derived sample temperature given specific sample volume, or block, which uses the actual sample block temperature. The Biorad MyCycler employs multiple built-in utilities, such as self-diagnostics and storage of detailed run and validation reports, for optimal performance for PCR and other thermal cycling techniques.

Specification

Condition: Used
Droplet frequency: 37–43 kHz
Sorting type: True jet-in-air for high-performance sorting
Sorting rate: No hardware limitations for sort rate, limited only by droplet frequency and application
Sorting purity: >99% pure
Nozzle size: 100 µm
Sorting direction: 2-way sorting
Sorting collection:
Up to 5 x 5 ml sample tubes each direction
Up to 5 x 1.5 ml tubes each direction
Microscope slides
8-well strip each direction
Lasers:
Single-laser: 488 nm 100 mW
Single-laser upgrade: 488 nm 100 mW plus 561 or 640 nm 100 mW
Dual-laser: 488 and 561 or 640 nm 100 mW
Tri-laser: 405, 488, and 561 or 405, 488, and 640 or 488, 561, and 640 mW 100 mW
Detection:
Forward scatter (FSC) with PMT
Side scatter (SSC) with PMT
Up to 4 fluorescence detectors with PMT
Minimum resolution: 0.5 µm
Sensitivity: <125 MESF for FITC and PE
Temperature range:
Sample and collection temperature control system: 4–37°C
Peltier solid state system
Fluidics: Onboard fluidics and dilution of 8x sheath fluid with deionized water
Data format: FCS 3.1
Dimensions: 70 x 65 x 65 cm (2.3 x 2.1 x 2.1 ft)

Related Products

Bio-Rad iCycler Thermal Cycler Biorad Ver. 4.006 (CAT#: STEM-PCREPO-0120-YJL)
Bio-Rad Dyad Disciple Peltier Thermal Cycler In Elkin, NC, USA (CAT#: STEM-PCREPO-0121-YJL)
Bio Rad C1000 Touch Thermal Cycler w/ 96 Well Block #1 In Jessup, MD, USA (CAT#: STEM-PCREPO-0122-YJL)
Bio-Rad Icycler 96 Thermal Cycler In Riverview, FL, USA (CAT#: STEM-PCREPO-0123-YJL)
Bio Rad C1000 Touch Thermal Cycler w/ 96 Well Block #2 In Jessup, MD, USA (CAT#: STEM-PCREPO-0125-YJL)
Biorad MyCycler Thermal Cycler In Stanwood, WA, USA (CAT#: STEM-PCREPO-0127-YJL)
BioRad iCycler PCR Thermal Cycler System In Ramsey, MN, USA (CAT#: STEM-PCREPO-0128-YJL)
Advertisement