Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Drager Infinity M300, Dräger (CAT#: STEM-MEMEPO-0006-ZJF)

Highlights

Built-in color screen with waveforms and vital sign values, providing local surveillance to augment monitoring at the Infinity CentralStation.
Visible and audible alarms that immediately alert you to changes in the patient's condition.
Integrated Arrhythmia Classification Expert (ACE®) and pacer detection algorithms.

Cat Number: STEM-MEMEPO-0006-ZJF

Application: For patient monitoring

Model: Infinity M300

Add to Cart



Description

The manufacturer of the Drager Infinity M300is Dräger.
The Drager Infinity M300 is a hand-held pulse oximeter and patient monitor that has the ability to monitor ECG, Heart rate, SpO2. The M300 system uses wireless network technology and a monitoring station to continuously monitor the patient even when out of range. The Drager M300 can be used on patients from pediatrics to adults. With a color display and a built-in alarm system, you can easily see and respond to the patient's needs.
The product is located in Irvine, CA, USA.

Specification

Condition: Certified Pre-owned
Dimensions
Height: 5.6 In (14.2 cm)
Width: 3 In (7.6 cm)
Depth: 1.2 In (3.1 cm)
Weight: 10.5 oz (295 g)
Display
Size / Viewing Area: 2.2 In (5.5 cm) diagonal
Resolution: 220 x 176 pixels
Communications
Network: IEEE 802.11b/g/n (2.4 GHz); 802.11a/n (5 GHz)
Wireless Encryption: WPA2 – Personal Mode; WPA2 – Enterprise Mode
Radio Power Output: (2.4 GHz); 25mW maximum (5 GHz)
Battery
Power Source: Rechargeable 3.75 V lithium-ion battery
Battery Operating Time:
ECG only: 17 to 19 hours
ECG + Continuous SpO2: 14 to 16 hours
Operation time varies according to use of display, alarm alerts, and wireless environment (roaming)
ECG
Adult / Pediatric
5-wire: I, II, III, aVR, aVL, aVF, V
6-wire: I, II, III, aVR, aVL, aVF, V, V+
6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV3, dV4, V5, dV6
Detected Events / Rhythms: Asystole, Ventricular Fibrillation, Ventricular Tachycardia, Bradycardia, Ventricular Run, Accelerated Idioventricular Rhythm, Supraventricular Tachycardia, Ventricular Couplet, Ventricular Bigeminy, Tachycardia, Pause, Artifact, PVC/min
Pacemaker
Detection Leads: I and (II or III)
Detection Amplitude: ±2 to ±700 mV
Detection Width: 0.1 to 2.0 ms
ST Segment Analysis
Leads Analyzed:
3-wire: I, II, or III
5-wire: I, II, III, aVR, aVL, aVF, V
6-wire: I, II, III, aVR, aVL, aVF, V, V+
6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV2, dV3, dV4, V5, dV6

Features

Built-in color screen with waveforms and vital sign values, providing local surveillance to augment monitoring at the Infinity CentralStation.
Visible and audible alarms that immediately alert you to changes in the patient's condition.
Integrated Arrhythmia Classification Expert (ACE®) and pacer detection algorithms.
Built-in SpO2, eliminating the need for an additional pulse oximetry device or module.
Wi-Fi CERTIFIED technology for reliable data transfer on standard wireless networks.
Support for WPA2 encryption using 802.11 b/g.

Related Products

Drager 8606055 O2 Sensor Housing, Dräger
Drager MS20783 Infinity Mcable Dual Hemo, Dräger
Drager 5-Lead ECG Cable, Dräger