The manufacturer of the HP 5890 II GCD Gas Chromatography Electron Ionization Detector, Hewlett Packard is Hewlett Packard. Hewlett Packard 5890 Series II GCD gas chromatography electron ionization detector (mass range of 10-400 amu) (m/n G1800A) including heated ion source, heated transfer line, analyzer, G1513A 6890 autosampler injector tower, G1512A autosampler controller, 18596C autosampler tray, Chemstation software, HP computer and manuals.
Specification
Condition: Refurbished, Certified Pre-owned Heated Devices: Five heated zones standard: Two detectors, Two inlets, one auxiliary Methods stored: Two Split/Splitless Capillary: Range to 400°C in 1°C increments Back-pressure design permits independent adjustment of split flow rate without affecting column flow Septum purge built in at 3 ml/min Accepts columns up to 1.2-mm od Multimode design includes split and splitless injection Splitless purge time variable in 0.01-min elements Flame Ionization Detector: Range to 450°C Grounded jet and current limited design for operator safety Push-button flame ignition Sensitive: 18 mCoul/gm carbon: nitrogen carrier, 0.018-in. id jet 15 mCoul/gm carbon: helium carrier, 0.018-in. id jet 22mCoul/gm carbon: nitrogen carrier, 0.018-in. id capillary jet 18 mCoul/gm carbon: helium carrier, 0.018-in. id capillary jet Minimum detectable: 5 pg carbon/sec, nitrogen carrier at S/N=2 Linear dynamic range: +/- 10% over a 10 7 range with 0.018-in. id jet Conditions: column flow 50 ml/min, 45 ml/min H2, 650 ml/min air, propane sample Thermal Conductivity Detector: Range to 400 °C Single-filament (single column) design has fluidic switching of reference and analytical carrier flows Minimum detectable : 400 pg/ml carrier -- equivalent to 1 pmm neon in 1 ml air Linear dynamic range: +/- 5% over 105 range Digital gain setting time-programmable through the keyboard Conditions: detector 100 °C, 45 ml/min switching and 30 ml/min analytical flow of helium, propane sample Flame Photometric Detector: Range to 300 °C 100-530 u id capillary columns fit through the transfer line to the base of the flame Two combustion modes: air/hydrogen or oxygen/hydrogen Detector signal display to view when flame is lit Push-button flame ignition Sulfur mode: Sensitivity to 20 pg S/second, Range 103, Selectivity 105 g S/g C Phosphorus mode: Sensitivity to 0.9 pg P/second, Range 104, Selectivity 106 g P/g C Column Oven: Operating range: 4 °C above ambient to 450 °C Setpoint entry: 1 °C for temperatures, 0.1 °C for program rates Programming: Rates 0.1 to 70 °C per min, 650 min maximum run time, Three ramps with initial/final holds
Features
Refurbished to meet manufacturer's specification In excellent condition Thoroughly cleaned Money back guarantee Certified with warranty
Related Products
HP 5890 II 5890A Gas Chromatograph, Hewlett Packard HP 5890 II Plus Gas Chromatograph, Hewlett Packard HP 5890 II TCD-FID, Hewlett Packard