Highlights

The Life Express Thermal Cycler is a thermoelectric cooling thermal cycler.
It features:
Reliable and stable operation, because the thermoelectric module is manufactured via the U.S. ITI's thermoelectric cooling technique and the Japanese quality management model;

Cat Number: STEM-PCRE-0147-LKN

Application: Nucleic acid amplification.

Model: TC-96/G/H(b)

Add to Cart



Specification

Sample capacity: 96-PCR plate (skirtless), 96*0.2ml tubes, 12*8-strip
Temp. range: 4°C~99°C
Heating speed of ramping: ≥ 3°C/sec
Cooling speed of ramping: ≥ 2°C/sec
Temp. uniformity: ≤±0.3°C(55°C)
Temp. accuracy:: ≤±0.3°C
Temp. control modes: BLOCK or TUBE
Max. No. of cycle: 99
Gradient. Range: 1~ 30°C
Hot-lid temp. range: 30~ 110°C
Height of hot lid: Adjusted
Communication Interface: RS232
Power supply: 220V, 50Hz, 600W
Dimensions: 345×250×270mm (L×W×H)
Net Weight: 7.3kg

Features

The Life Express Thermal Cycler is a thermoelectric cooling thermal cycler.
It features:
Reliable and stable operation, because the thermoelectric module is manufactured via the U.S. ITI's thermoelectric cooling technique and the Japanese quality management model;
High heating/cooling (heating rate ≥2.0°C/sec., and cooling rate ≥ 1.5°C/sec.), which greatly reduces experimental time;
Automatic temperature ramp control, which allows different heating/cooling ramp settings so that the device can emulate other thermal cycler's temperature control process;
Automatic temperature and time increments/decrements during cycling program execution, optimizing the PCR amplification conditions;
Automatic link among files, allowing a complex PCR amplification program to be executed;
The soak mode at a temperature up to 4°C without human interference, after normal cycling program execution;
Instant inspection of total execution time and remaining execution time;
Optional heated lid, preventing the sample in a centrifugal tube from evaporation, which makes paraffin oil unnecessary and operation more convenient, and reduces the sample processing time;
Auto-restart in case of power failure, restoring the data before interrupting and continuing to perform the previously interrupted program.