This service uses gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) to measure the 13C/12C ratios of chloroacetic acids (CAAs). CAAs are a major class of environmental pollutants that are widely distributed throughout the world, often at relatively high concentrations, and are of concern due to their toxic effects, particularly on plants. The 13C/12C of CAA reagents was measured by IRMS subsequent to offline combustion. Aqueous solutions of these CAAs were derivatized to the corresponding methyl chloroacetates (MCAAs) with acidic methanol with a known isotopic composition, extracted into pentane, and analyzed by GC/C/IRMS. Measured 13C/12C ratios of derivatized MCAAs were in agreement with calculated values within 1 per thousand for monochloroacetic acid and trichloroacetic acid and within 2 per thousand for dichloroacetic acid, suggesting that methylation and other analytical methodology steps do not isotopically fractionate derivatized MCAAs. 13C/12C ratios of reagent CAAs from different sources had varying isotopic signatures suggesting differences in source carbon and/or production methods. Our results underscore the potential of stable isotopes to serve as tracers of environmental sources of CAAs.