Molecular Devices SpectraMax 190 Microplate Reader, 190 – 850 nm, model SpectraMax 190, is manufactured by Molecular Devices. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. Capable of detecting DNA down to 25 ng per well, this model gives users the same sensitivity as conventional systems to produce accurate nucleic acid measurements. Molecular Devices’ PathCheck® sensor technology found in every SpectraMax® 190 improves precision when handling aqueous solutions. This innovative feature enables the model to sense the depth of liquid in each microplate as well as to normalize the absorbance value to 1-cm pathlength. The corrected absorbance is within 5% of the value obtained in a conventional spectrophotometer. Instrument linearity is also extended by a factor of three or more with PathCheck® sensors. Highly concentrated samples use a minimum volume in the microplate well or 100 µl which has a pathlength of approximately 0.30 cm. This sensor technology yields calculated absorbance values well beyond the capabilities of other instruments by calculating an equivalent 1-cm pathlength absorbance value. Industry leading microplate analysis software provides the SpectraMax 190 with a means for comprehensive instrument control and data reduction. Spectral scanning makes assay development easy. Operators can select the optimum wavelength for reading any assay by viewing the complete spectrum of the sample. This method enables equipment operators to monitor the stability of samples or reagents and to determine interfering compounds or conditions of assays. Spectral scanning can also be used to compare assay results to regulatory standards.
Specification
Condition: Certified Pre-Owned Dimensions ( H x W x D): 8.6 x 22.8 x 15 (in.); 22 x 58 x 38 (cm) Weight: 30 lbs. (13.6 kg) Power requirements: 90 – 250 VAC 50/60 Hz Power consumption: < 250 watts Operating temperature: 10 – 40 ℃ Storage temperature: 5 – 40 ℃ Photometric Performance Wavelength Range: 190 – 850 nm Wavelength Selection: Monochromator, tunable in 1 nm increments Wavelength Bandwidth: 2 nm Wavelength Accuracy Wavelength Repeatability: ± 0.2 nm Photometric Range: 0 – 4.0 OD Photometric Resolution: 0.001 OD Photometric Linearity (405 nm): 0 – 3.000 OD Photometric Accuracy (190 – 850 nm) Photometric Precision (190 – 850 nm) PathCheck Sensor Management Error: < 5% compared to cuvette reading Stray light: ≤ 0.05% @ 230 nm Light source: Xenon flash lamp Microplate Read Times Endpoint: 12 seconds Kinetics: 9 second minimum interval Temperature Specifications Temperature Range: Ambient + 4 – 45℃ Temperature Uniformity (microplate): ± 0.5℃ at 37℃, well-to-well Temperature Stabilization Time: 30 minutes maximum upon initiation Reading Chambers: Isothermal when temperature regulation not enabled, < 1℃
Features
Compatible with Molecular Devices’ StakMax® Microplate Stacker Performs a wide range of UV/VIS Assay Procedures Detects pipetting errors Equipped with a PathCheck® Sensor Boasts of a multi-channel design