Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

O.I. 4560 Sample Concentrator, O. I. Corporation (CAT#: STEM-CPO-0292-ZJF)

Highlights

Built-in Cyclone Water ManagementTM minimizes the amount of water transferred to the analytical column and detector.
Uses 5- and 25-mL frit and needle spargers and disposable tube spargers, using the same length needle and “wide-neck” 18-mm mount.
Handles sample foaming and spillover through a removable particle foam filter in the sample inlet.

Cat Number: STEM-CPO-0292-ZJF

Application: For gas chromatography

Model: O.I. 4560

Add to Cart



Description

The manufacturer of the O.I. 4560 Sample Concentrator, O. I. Corporation is O. I. Corporation.
O.I. 4560A with DPM-16 and heaters.
The O.I. Analytical Model 4560 Sample Concentrator thermally traps and desorbs organic compounds for GC and GC/MS analysis.
The Model 4560 Purge-and-Trap Sample Concentrator collects and transfers volatile organic compounds to a GC or GC/MS for analysis. It is specifically designed to purge volatiles from water, soil, and air for concentration onto a sorbent trap in compliance with USEPA protocol. The sample transfer line connects directly to the column or through an optional Low-Dead-Volume InjectorTM to the GC column in an analytical system.

Specification

Condition: Refurbished, Certified Pre-owned
Optional: O.I. MHC-16 heaters and multiple heater controller.

Features

Built-in Cyclone Water ManagementTM minimizes the amount of water transferred to the analytical column and detector.
Uses 5- and 25-mL frit and needle spargers and disposable tube spargers, using the same length needle and “wide-neck” 18-mm mount.
Handles sample foaming and spillover through a removable particle foam filter in the sample inlet.
Provides controlled temperature of each heated zone.
Processor-controlled and fully interactive via the RS-232-C communication port.
Basic operational sequence is controlled by key entry; operator interface is simple to use and vacuum-fluorescent display is easy to read. 2 Model 4560 Sample Concentrator Operator’s Manual Rev. 2.3
Up to 14 sets of run settings can be saved, loaded as files, and even sequenced during a multisampler run.
Rapid trap heating (900°C/min) and cooling (250°C/min) optimizes chromatography and reduces run times.
All lines contacting the sample are inert and impermeable to gases.
Incorporates power-up self-test and diagnostics messages.
Optional Internal Carrier Flow Controller allows all gases (purge and carrier) to be provided by and monitored through the sample concentrator.
Incorporates BCD inputs for multisampler position monitoring.

Related Products

O.I. 4460 Detector, O. I. Corporation
PE 8500 FID Gas Chromatograph, Perkin Elmer
PE Autosystem, Perkin Elmer

Other recommended products

Advertisement