The Ortho VITROS® chemistry, immunoassay and integrated system reduces potential errors and the need for repeat testing to increase first-time pass rates, reduce costs, and improve turnaround time.
Main advantages:
The VITROS® system requires no water, reducing costs and waste disposal while remaining environmentally friendly. 96.5% first pass rate (results delivered without user intervention) - the highest in the industry. VITROS® XT solutions provide up to 25% faster turnaround times* on common test panels compared to competing systems. Sample volume per test is low (2-80 μl). The new VITROS® XT analyzer offers up to 40% higher throughput, improving laboratory efficiency. The comprehensive test menu includes SARS-CoV-2 IgG and total antibodies, HIV combination, B·R·A·H·M·S procalcitonin, immunosuppressive drugs and drugs of abuse. *TAT completes these tests: glucose, calcium, albumin, total protein, sodium, potassium, carbon dioxide, chlorine, blood urea nitrogen, creatinine, alkaline phosphatase, alanine aminotransferase, bilirubin.
Whether routine or specialty immunodiagnostic testing, accurate results are critical to physicians and patients as their treatment decisions depend on them. The VITROS® ECiQ Immunodiagnostic System is a versatile system that validates and documents each step throughout the process. This means you can rely on the integrity and quality of results you need to confidently deliver results that matter.
Specification
Condition: certified pre-owned Dimensions W x D x H: 111.8cm x 73.7cm x 130.2cm (44 in x 29 in x 51.25 in) Weight: 366 kg (807 lb) Line voltage: Dedicated, single-phase AC power line; North America: 120 V AC; Continental Europe: 200–240 V AC Line frequency: North America: 50–60 Hz; Continental Europe: 50–60 Hz Average heat output: 4100 BTUs per hour Operating temperature: 15°–30°C (59°–86°F) Ambient relative humidity: 15%–75% RH noncondensing Altitude: -0.1524/2.439 km (-500/8000 ft) Plumbing: No water or drain required; self-contained onboard waste management eliminates special requirements for offboard plumbing Reagents: No preparation, no mixing or reconstitution required for Integrated Reagent Packs, Signal Reagent, and Universal Wash Reagent Onboard test capacity: Up to 2,000 assays; Up to 20 different Integrated Reagent Packs (100 assays each; resident on-board simultaneously; automatic, self-contained, temperature and humidity controlled Reagent Supply) Calibration: Multiple lots may be precalibrated with automatic lot switching; Up to 28 days; Process: Random Access Calibration with Automatic Result Protection; 25 calibrations across 16 lots per assay Throughput: Up to 90 reportable patient results per hour Sample capacity: 60 samples in universal trays Universal sample trays: Accomodate 5mL, 7mL, and 10mL collection tubes; 1.5mL microcollection containers; VITROS® microsample cups and 0.5mL and 2.0mL cups Laboratory Information System (LIS): Bidirectional interface for ASTM and Kermit protocols; Broadcast download 4 RS 232 serial ports