Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Perkin Elmer MicroBeta2 1450-0020 Microplate Reader, Perkin Elmer (CAT#: STEM-S-0701-LGZ)

Highlights

1. A powerful multitasking system.
2. Advanced detectors - beta and gamma isotopes as well as luminescent chemiluminescence and flash chemiluminescence can be detected.
3. Filter-Based Receptor Binding Assays - Use UniFilter Well Plates or MicroBeta Flitermate to increase sensitivity.

Cat Number: STEM-S-0701-LGZ

Application: For solid phase homogenization experiments, cell proliferation, cytotoxicity, reporter gene analysis, metabolic studies, liquid scintillation counting, swab tests, ELISA, kinase assays, radioimmunoassay (RIA).

Model: MicroBeta2 1450-0020

Add to Cart



Description

The manufacturer of Perkin Elmer MicroBeta2 1450-0020 Microplate Reader is Perkin Elmer. Model is MicroBeta2 1450-0020. The MicroBeta2 system supports coincidence counting, a unique patented configuration with two simultaneous signal detection photomultiplier tubes, ensuring high efficiency and very low background values for various radionuclides. In addition, it has time-resolved liquid scintillation counting (TR-LSC) capability, providing excellent counting performance for opaque plates where conventional coincidence counting is not possible.

Specification

Condition: used
21 CFR Part 11 Compatible: Yes
Detector type: 2 Detectors
Height: 609.0 mm
Length: 645.0 mm
Portable: No
Width: 433.0 mm

Features

1. A powerful multitasking system.
2. Advanced detectors - beta and gamma isotopes as well as luminescent chemiluminescence and flash chemiluminescence can be detected.
3. Filter-Based Receptor Binding Assays - Use UniFilter Well Plates or MicroBeta Flitermate to increase sensitivity.
4. Solid Phase Homogenization Assays - Provides best-in-class detection performance in all solid-state scintillation assays, including bead-based scintillation proximity assays and scintillation plate assays.
5. Cell Proliferation - Cell proliferation was analyzed through a 3H-labeled thymidine kinase uptake filter.
6. Cytotoxicity - Cytotoxic release 51Cr assay was performed using LumaPlate or liquid scintillation counting (LSC).
7. Reporter Gene Assay - Fluorescent Chemiluminescence and Flash Chemiluminescence with Dual Reporter Gene Assay using Luciferase and β-Lactamase.
8. Metabolism studies - HPLC fraction measurements on 4 mL vials using LumaPlate or traditional scintillation-based methods.
9. Liquid scintillation counting - reduces traditional vial-based liquid scintillation counting analysis to microplates.
10. Swab Test - Additional counters to monitor laboratory contamination are not required.
11. More other options - ELISA, kinase assay, radioimmunoassay (RIA) etc.
12. Select the appropriate membrane type from different filter plates, such as UniFilter plates or special filter plates for microbeta2.
13. Use LSC small vials (4 mL) to reduce vial count analysis to increase throughput.

Related Products

Tecan Sunrise Microplate Visible/Absorbance Reader, Tecan(CAT#-STEM-S-0741-LGZ)
Molecular Devices ThermoMax Microplate Visible/Absorbance Reader, Molecular Devices(CAT#-STEM-S-0742-LGZ)
Molecular Devices Vmax Microplate Visible/Absorbance Reader, Molecular Devices(CAT#-STEM-S-0743-LGZ)
Varian 50 Bio Spectrophotometer UV/Vis Reader, Varian(CAT#-STEM-S-1408-LGZ)
Beckman Coulter DU 800 Spectrophotometer UV/Vis Reader, Beckman Coulter(CAT#-STEM-S-1417-LGZ)
Thermo Scientific Evolution 201 Spectrophotometer UV/Vis Reader, Thermo Fisher Scientific(CAT#-STEM-S-1418-LGZ)
Advertisement