Persee T9DCS Spectrophotometer UV/Vis Reader, Persee (CAT#: STEM-S-1442-LGZ)

Highlights

1. True dual beam dual monochromatic optics, fully sealed, provides ultra-low stray light (0.00004% T @220 nm) and high photometric range (-8.0~8.0 Abs).
2. The wavelength range is 185 - 900 nm, nitrogen purged.
3. The integrated mercury lamp is used for automatic calibration, and the precise wavelength is guaranteed.

Cat Number: STEM-S-1442-LGZ

Application: For photometric measurements, spectrum scans, quantitative determinations and DNA/Protein analysis.

Model: T9DCS

Add to Cart



Description

The manufacturer of Persee T9DCS Spectrophotometer UV/Vis Reader is Persee. Model is T9DCS. The T9/T10DCS spectrophotometer incorporates dual monochromatic technology, making it ideal for even the most demanding applications in all areas of the UV-Vis spectrum. The optical design of both T9DCS and T10DCS provides extremely low stray light characteristics (≤0.00004%T NaI, 220 nm), allowing a wide photometric range (-8.0 - 8.0 Abs). Measuring deep UV wavelengths can also be achieved using nitrogen to purge the optics. The instrument can be optically configured to suit the needs of the sample with a continuously adjustable slit for precise control of spectral resolution and beam size adjustment via an attenuation wheel.

Specification

Condition: used
Optical system: Double beam
Scan Speed: 1000 nm/min, 1500 nm/min location speed
Wavelength Range: 185-900 nm
Wavelength Accuracy: ±0.2 nm
Spectral Bandwidth: ±20 % (0.1 nm-5 nm continuously adjustable)
Photometric Model: Transmittance,Absorbance, Enegy and Concentration
Photometric Range: -6.0 Abs-6.0 Abs
Baseline Flatness: ±0.0008 Abs
Baseline Stability: 0.1 %/hr
Cell Holder: Automatic 8 Cell Changer

Features

1. True dual beam dual monochromatic optics, fully sealed, provides ultra-low stray light (0.00004% T @220 nm) and high photometric range (-8.0~8.0 Abs).
2. The wavelength range is 185 - 900 nm, nitrogen purged.
3. The integrated mercury lamp is used for automatic calibration, and the precise wavelength is guaranteed.
4. The spectral bandwidth of 0.1-5 nm can be continuously selected.
5. The beam size is continuously adjustable for a variety of applications, including ultra-large volume colorimeters.
6. Large sample chamber, suitable for various accessories, especially 150mm integrating sphere.
7. Support on-site WIFI communication.
8. Integrated mercury lamp with automatic correction function to ensure precise wavelength accuracy.

Related Products

Molecular Devices Spectramax Plus 384 Microplate UV/VIS Reader, Molecular Devices(CAT#-STEM-S-0740-LGZ)
Tecan Sunrise Microplate Visible/Absorbance Reader, Tecan(CAT#-STEM-S-0741-LGZ)
Molecular Devices ThermoMax Microplate Visible/Absorbance Reader, Molecular Devices(CAT#-STEM-S-0742-LGZ)
Molecular Devices Vmax Microplate Visible/Absorbance Reader, Molecular Devices(CAT#-STEM-S-0743-LGZ)
Varian 50 Bio Spectrophotometer UV/Vis Reader, Varian(CAT#-STEM-S-1408-LGZ)
Beckman Coulter DU 800 Spectrophotometer UV/Vis Reader, Beckman Coulter(CAT#-STEM-S-1417-LGZ)
Advertisement