The manufacturer of the SIL-HTc Autosampler, Shimadzu is Shimadzu. Refurbished Shimadzu SIL-HTc Prominence thermostatted autosampler with built-in controller. (available cat numbers: 228-41001-32 & 228-45062-32). The SIL HTc is the autosampler for Shimadzu Prominence Series, HPLC System and LCMS. High throughput is the key word for modern HPLC analysis. The SIL-HT is the best performing autosampler in terms of sample injection speed, sample capacity, and minimizing sample carryover of highly absorbent sample components. These features are in increasingly high demand and essential for high throughput analysis. The SIL-HT has been developed to meet such users' requirements and will also provide optimum results in your lab. The SIL-HT is available in two versions: the SIL-HTA, ambient model; and the SIL-HTC with sample temperature control from 4 to 40C.
Specification
Condition: Refurbished, Certified Pre-owned Sample injection system: Total sample injection, variable sample injection system (zero sample loss during injection) Settable range of injection volumes: 0.1 to 100 µL (standard), or 1 to 2000 µL (option) (0.1µL steps from 0.1 to 0.9µL, and 1µL steps from 1 to 2000 µL) Sample processing capability: With 1-mL vials: 350 With 1.5-mL vials: 140 With 4-mL vials: 100 With micro plates: 4 (96 wells: 284, 284 wells: 1536) with deep well plates: 4 (96 wells: 284, 284 wells: 1536) Injection volume repeatability: RSD: 0.3% max. (at 10µL injection) Cross contamination: 0.01% max. (for analysis of naphthalene) Injection volume accuracy: Less than +/- 1% (50µL) Injection volume accuracy correction: Possible No. of injections: 1-99 times per sample Setting of analysis time: 0.01 – 9999.9 (0.1 minute increments to 999.99 min., 0.1 minutes increments over 1000 min.) Number of steps for injection conditions: Max 102 steps Sample suction speed: 0.1-15 µL/sec (0.1µL/s step for 0.1-0.9 µL/sec., 1µL/s step for over1 µL/sec.) Rinsing liquid suction speed: 1-35 µL/sec/ (1µL/s step) Maximum pressure: Max. 20.0 Mpa (standard pippings of sample flowpath is PEEK) Sample cooler: Direct cooling method (at a setting of 4 deg. C, room temperature must be less than 30 deg. Cand humidity less than 70%) Temperature setting range: 4 to 40 deg. (cooling down to 4 deg. C for room temperature up to 30 deg. C and humidity to 70%) Operating ambient temperature range: 4 to 35 deg. C Optional: 70 position vial sample trays
Features
Refurbished to meet manufacturer's specification In excellent condition Thoroughly cleaned Money back guarantee Certified with warranty