Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Thermo LTQ FT LC/MS/MS Mass Spectrometer, Thermo Fisher Scientific (CAT#: STEM-MSPO-0105-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-MSPO-0105-ZJF

Application: For measuring the mass-to-charge ratio (m/z) of one or more molecules present in a sample

Add to Cart



Description

The manufacturer of the Thermo LTQ FT LC/MS/MS Mass Spectrometer, Thermo Fisher Scientific is Thermo Fisher Scientific.
Refurbished Thermo Finnigan LTQ-FT mass spectrometer (p/n 2066940-E0) complete with Oxford 7T FT-ICR (p/n AJH0280 59-A30085 1150740), ESI probe with housing, Edwards E2M30 pumps, Pfeiffer Duo 25 pump, Windows XP PC workstation, HP Laserjet Printer 2300d, Dell 19" LCD monitor, Xcalibur 2.0 software with license, LTQ-FT 2.5 instrument software and manuals.
The LTQ-FT is capable of simutaneous high resolution, mass accuracy, and sensitivity over one mass decade (e.g. m/z 200 - m/z 2000). It has a fast data acquisition rate (1 second repetition rate) with very high resolution (100,000 at m/z 400). The mass accuracy is better than 2 ppm with external calibration. Sensitivity is sub fmol on-column in LC/MS. It is cabable of simultaeous full scan FT MS, data dependent zoom scan, and MS/MS scans.
Optional: nanoESI sources (including static, dynamic, and packed tip) with a Pulnix video camera and has the standard Finnigan IonMax API source with the ESI attachment. Optional: The ICR cell has an Electron Capture Dissociation (ECD) emitter cathode attached to the back of the cell. The ECD method of fragmentation produces c and z ions. This method preserves co- and post-translational modifications (PTMs) such as phosporalation, O- and N-linked glycosalation and sulfation. The LTQ also has Wide Band Activation which allows the simultaneous fragmentation of a parent ion and its corresponding water loss peak by resonance excitation.

Specification

Condition: Refurbished, Certified Pre-owned
Resolution to 100000
Mass Accuracy 1-2 ppm with internal standard
Mass Accuracy <1 ppm Sim mode
Electron Capture Dissociation Capable
complete with Oxford 7T FT-ICR (p/n AJH0280 59-A30085 1150740)
ESI probe with housing
Edwards E2M30 pumps
Pfeiffer Duo 25 pump
Windows XP PC workstation
HP Laserjet Printer 2300d
Dell 19" LCD monitor
Xcalibur 2.0 software with license
LTQ-FT 2.5 instrument software and manuals
Optional: ECD
Nano Spray source
Michrom Bioresources CaptiveSpray ion source (p/n SS2/00003/00)
XCalibur 2.2 with Windows 7

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty

Related Products

Thermo LTQ Linear Ion Trap Mass Spectrometer, Thermo Fisher Scientific
Thermo LTQ-FT Ultra Mass Spectrometer, Thermo Fisher Scientific
Thermo LXQ Inear Ion Trap Mass Spectrometer, Thermo Fisher Scientific
Advertisement