Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Ultimate 3000 RS Pump, Dionex (CAT#: STEM-CPO-0698-ZJF)

Highlights

Injection volume precision typically <0.15% RSD for 5 μL injections
Superior injection linearity of r 2 >0.9999 (5–90 μL) due to high-precision drive mechanism
Wide injection volume range from 1–100 μL (default configuration) for maximum injection flexibility

Cat Number: STEM-CPO-0698-ZJF

Application: For chromatography

Model: Ultimate 3000 RS

Add to Cart



Description

The manufacturer of the Ultimate 3000 RS Pump, Dionex is Dionex.
Refurbished Dionex Ultimate 3000 RS Pump (DGP-3600RS) (p/n 5040.0066) 15,000 psi (~1000 bar).
The UltiMate ® 3000 Rapid Separation Autosampler is the only UHPLC autosampler that robustly injects up to 500 μL at pressures up to 15,000 psi (103.4 MPa). This wide injection-volume flexibility makes the module suitable for both UHPLC and conventional HPLC applications. The in-line split-loop (or flow-through) injection design of the module provides highly accurate and precise delivery of the sample with ultralow carryover.

Specification

Condition: Refurbished, Certified Pre-owned
Sample Capacity:
216 × 0.3 mL vials,
120 × 1.1 mL conical vials,
216 × 1.2 mL vials,
120 × 1.8 mL/2.0 mL vials,
66 × 4 mL vials,
30 × 10 mL vials,
3 x 24 deep well plates, 96 and/or 384 normal or deep well plates,
3 x 40 0.5 mL and/or 1.5 mL Eppendorf tubes, and/or 3 x 384 low well PCR plates
+ 15 × 10 mL vials (depending on sample tray configuration)
Dimensions (h x w x d): 10 x 42 x 51 cm (3.9 x 16.5 x 20 in.)
Weight: With internal degasser: 4.8 kg (10.6 lb)

Features

Injection volume precision typically <0.15% RSD for 5 μL injections
Superior injection linearity of r 2 >0.9999 (5–90 μL) due to high-precision drive mechanism
Wide injection volume range from 1–100 μL (default configuration) for maximum injection flexibility
Optional injection volume ranges of 0.2–25 μL, 1.5–200 μL, and 1.5–500 μL available
Low gradient delay volume of 140 μL (default configuration) or 50 μL (with 25 μL sample loop)
Volumetric accuracy better than ±0.5% for 20 μL injections for easy method transfer
Supports well plates and short injection cycle times for high-throughput applications
Sample thermostatting for optimal protection of thermally-sensitive analytes (WPS-3000TRS)