G1376A Capillary Pump, Agilent Technologies (CAT#: STEM-CPO-0528-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-CPO-0528-ZJF

Application: For chromatography

Model: G1376A

Add to Cart



Description

The manufacturer of the G1376A Capillary Pump, Agilent Technologies is Agilent Technologies.
Refurbished Agilent 1100 Series G1376A capillary pump. Refurbished and demo modules available.
The Agilent 1100 Series capillary LC pump offers better control and flexibility of low flow rates. The pump is ideally suited for capillary LC and LC/MS applications. This unit offers optimized flow rates from 1 μl/min up to 20 μl/min in capillary mode and in normal mode up to 2.5 ml/min for highest flexibility in gradient work.

Specification

Condition: Refurbished, Certified Pre-owned
Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
Settable column flow Range:
0.01 – 20 µl/min
0.01 – 100 µl/min (with the extended flow range kit)
0.001 – 2.5 µl/min (with the electronic flow control bypassed)
Recommended column flow range:
1 – 20 µl/min
10 – 100 µl/min (with extended flow range kit)
0.1 – 2.5 ml/min (with the electronic flow sensor bypassed)
Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
Delay volume:
Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
For flow rates up to 100 µl/min and electronic flow control active:
Primary flow path 180 – 480 µl without mixer, 600 – 900 µl with mixer (system pressure dependent)
Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
Pressure range: 20 to 400 bar (5880psi) system pressure
Compressibility Compensation: User-selectable, based on mobile phase compressibility
Recommended pH Range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
Control and data Evaluation: Agilent ChemStation for LC
Analog output: For pressure monitoring, 2 mV/bar, one output
Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Glp features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
Housing: All materials recyclable
Optional: G1376-68705 accessories kit

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty

Related Products

G1367C HiP-ALS SL Autosampler, Agilent Technologies
G1377A Micro Well-Plate Autosampler, Agilent Technologies
G1378A Thermostatted Micro Well-plate Sampler, Agilent Technologies

Other recommended products

Advertisement